Daikin VRV II RXYQ5MATL Service Manual page 27

R-410a heat pump 60hz
Table of Contents

Advertisement

Specifications
Model Name (Combination Unit)
Model Name (Independent Unit)
1 Cooling Capacity (19.5°CWB)
2 Cooling Capacity (19.0°CWB)
3 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Heat Exchanger
Type
Piston Displacement
Number of Revolutions
Comp.
Motor Output×Number
of Units
Starting Method
Type
Motor Output
Fan
Air Flow Rate
Drive
Liquid Pipe
Connecting
Pipes
Gas Pipe
Product Mass (Machine Weight)
4 Sound Level
Safety Devices
Defrost Method
Capacity Control
Refrigerant Name
Refrigerant
Charge
Control
Refrigerator Oil
Standard Accessories
Drawing No.
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level difference :
4 Sound level : Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height
5 The units with anti-corrosion treatment will be available as standard. Please specify the suffix "E" as
16
RXYQ30MAYL(E)
RXYQ30MATL(E)
RXYQ14MAYL(E)+RXYQ16MAYL(E)
RXYQ14MATL(E)+RXYQ16MATL(E)
kcal / h
Btu / h
kW
kW
kcal / h
Btu / h
kW
Ivory White (5Y7.5/1)
mm
(1600×1240×765)+(1600×1240×765)
Cross Fin Coil
Hermetically Sealed Scroll Type
m³/h
(13.72+10.53+10.53)×2
r.p.m
(6480, 2900×2)×2
kW
(1.1+4.5+4.5)+(2.7+4.5+4.5)
Direct on line (Inverter Drive)
Propeller Fan
kW
m³/min
Direct Drive
φ19.1 (Brazing Connection)
mm
φ34.9 (Brazing Connection)
mm
kg
dBA
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
%
kg
Electronic Expansion Valve
Refer to the nameplate of compressor
Installation Manual, Operation Manual, Connection Pipes,
Clamps
YL(E)
C : 4D049805, 4D049806
TL(E)
C : 4D049811, 4D049812
difference : 0m.
difference : 0m.
0m.
of 1.5m. The Sound level of "Combination Unit" is a supposed value. During actual operation, these
values are normally somewhat higher as a result of ambient conditions.
RXYQ5MAYLE, TLE.
73,500
292,000
85.5
85.0
81,700
324,000
95.0
0.75×2
210+210
312+312
63
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
Deicer
5~100
R-410A
11.6+12.4
Installation Manual, Operation Manual, Connection Pipes,
Clamps
RXYQ32MAYL(E)
RXYQ32MATL(E)
RXYQ16MAYL(E)+RXYQ16MAYL(E)
RXYQ16MATL(E)+RXYQ16MATL(E)
77,800
309,000
90.5
90.0
86,000
341,000
100
Ivory White (5Y7.5/1)
(1600×1240×765)+(1600×1240×765)
Cross Fin Coil
Hermetically Sealed Scroll Type
(13.72+10.53+10.53)×2
(6480, 2900×2)×2
(2.7+4.5+4.5)+(2.7+4.5+4.5)
Direct on line (Inverter Drive)
Propeller Fan
0.75×2
210+210
Direct Drive
φ19.1 (Brazing Connection)
φ34.9 (Brazing Connection)
312+312
63
Deicer
5~100
R-410A
12.4+12.4
Electronic Expansion Valve
Refer to the nameplate of compressor
C : 4D049806
C : 4D049812
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3