Daikin VRV II RXYQ5MATL Service Manual page 24

R-410a heat pump 60hz
Table of Contents

Advertisement

Si39-504
Model Name (Combination Unit)
Model Name (Independent Unit)
1 Cooling Capacity (19.5°CWB)
2 Cooling Capacity (19.0°CWB)
3 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Heat Exchanger
Type
Piston Displacement
Number of Revolutions
Comp.
Motor Output×Number
of Units
Starting Method
Type
Motor Output
Fan
Air Flow Rate
Drive
Liquid Pipe
Connecting
Pipes
Gas Pipe
Product Mass (Machine Weight)
4 Sound Level
Safety Devices
Defrost Method
Capacity Control
Refrigerant Name
Refrigerant
Charge
Control
Refrigerator Oil
Standard Accessories
Drawing No.
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level difference :
4 Sound level : Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height
5 The units with anti-corrosion treatment will be available as standard. Please specify the suffix "E" as
Specifications
RXYQ18MAYL(E)
RXYQ18MATL(E)
RXYQ8MAYL(E)+RXYQ10MAYL(E)
RXYQ8MATL(E)+RXYQ10MATL(E)
kcal / h
Btu / h
kW
kW
kcal / h
Btu / h
kW
Ivory White (5Y7.5/1)
mm
(1600×930×765)+(1600×930×765)
Cross Fin Coil
Hermetically Sealed Scroll Type
m³/h
(13.72+10.53)×2
r.p.m
(6480, 2900)×2
kW
(0.7+4.5)+(1.6+4.5)
Direct on line (Inverter Drive)
Propeller Fan
kW
m³/min
Direct Drive
φ15.9 (Brazing Connection)
mm
φ28.6 (Brazing Connection)
mm
kg
dBA
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
%
kg
Electronic Expansion Valve
Refer to the nameplate of compressor
Installation Manual, Operation Manual, Connection Pipes,
Clamps
YL(E)
C : 4D049802, 4D049803
TL(E)
C : 4D049808, 4D049809
difference : 0m.
difference : 0m.
0m.
of 1.5m. The Sound level of "Combination Unit" is a supposed value. During actual operation, these
values are normally somewhat higher as a result of ambient conditions.
RXYQ5MAYLE, TLE.
46,000
183,000
53.5
53.2
51,500
204,000
59.9
0.75×2
175+180
230+230
61
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
Deicer
7~100
R-410A
7.6+8.6
Installation Manual, Operation Manual, Connection Pipes,
Clamps
Specifications
RXYQ20MAYL(E)
RXYQ20MATL(E)
RXYQ10MAYL(E)+RXYQ10MAYL(E)
RXYQ10MATL(E)+RXYQ10MATL(E)
48,400
192,000
56.3
56.0
54,200
215,000
63.0
Ivory White (5Y7.5/1)
(1600×930×765)+(1600×930×765)
Cross Fin Coil
Hermetically Sealed Scroll Type
(13.72+10.53)×2
(6480, 2900)×2
(1.6+4.5)×2
Direct on line (Inverter Drive)
Propeller Fan
0.75×2
180+180
Direct Drive
φ15.9 (Brazing Connection)
φ28.6 (Brazing Connection)
230+230
61
Deicer
7~100
R-410A
8.6+8.6
Electronic Expansion Valve
Refer to the nameplate of compressor
C : 4D049803
C : 4D049809
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3