HACCP(Hazard Analysis and Critical Control Points)
Temperature Sensor
Controller has input for HACCP temperature reading
to be reported out to system managers.
No control logic is active on this sensor.
Available Expansion Modules
HSVD20 - Dual Valve Driver
Used for additional IO for Micro-Distributed Setups.
Application
The application will have the option to support up to
three separate zones. To maintain case temperature,
the application will use discharge air temperatures and
safeties to manage cold operations.
Internal Web Server
The CoreLink case controller features a friendly user
interface that can be accessed by web browser.
This Web UI can be accessed by in store network via
windows computer or with a wireless link device that
can be viewed by technician through smart devices.
Data Logging
The case control application has internal logging for
each sensor along with critical operation data. Data is
available for local download.
→ 2-minute intervals
→ 14-day capacity
→ Advanced analytics; web user interface
→ CSV format with 15 critical data points
Onboard data logging allows user to review
performance data from the past week. User can see
Min/Max/Average data along with saving data sets and
importing data sets for view.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Factory Restore
The CoreLink application has a configuration file with
the complete and optimized default case settings.
Anytime a user wants to default to factory settings they
can simply access the user interface and force a factory
reset.
Save / Load Feature
The CoreLink Case Controller is setup from the factory
with a specific product configuration when a customer
purchases a display case.
This specific configuration is hardcoded into the
controller and is the factory default file. Also included
are three user presets that a user can save or load
custom configuration settings. These settings allow
customers to make small tweaks in the field that can
improve performance or target temperatures.
Standalone Operation
Controller is configured from the factory to run as
a standalone controller. Field network integrations
are done to provide additional capabilities to the
controller. In case of network failure of BAS managing
additional control functions, controller will default to
its standalone settings and regulate display case until
network connection is restored.
In case of network failure to building automation
system managing case setpoints, the controller will
default to program settings in internal memory and
continue to regulate display case until network con-
nection is restored.