9
These merchandisers are manufactured to meet ANSI/National Sanitation
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Specialty Products
R3M-F/CR3M-F
CUL Listed
UL Sanitation
Discharge Air (F)
Evaporator (F)
Discharge Air (F)
Evaporator (F)
Discharge Air (F)
Evaporator (F)
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft*
Parallel
Conventional
Parallel
Conventional
Parallel
Conventional
Hussmann, use conventional Btu values.
Frequency Hrs
OFFTIME
Temp Term °F
Failsafe Minutes
ELECTRIC or GAS
Merchandiser Drip Pipe (in.)
Merchandiser Liquid Line (in.)
Merchandiser Suction Line (in.)
Estimated Charge (lb)***
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
1 of 9
R3M-F/CR3M-F
Technical Data Sheet
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Front
24
20
Top
26
18
Rear Storage
30
20
Front
750
863
Top
250
288
Rear Storage
175
201
*For all refrigeration equipment other than
DEFROST DATA
Not Recommended
PHYSICAL DATA
4ft
1.2
5ft
1.5
6ft
1.8
Rev A
6
54
40
1 ½*
3/8*
5/8*

Advertisement

loading

Summary of Contents for Hussmann Specialty Products CR3M-F

  • Page 1 Btu/hr/ft* Parallel Conventional Parallel Conventional Rear Storage Parallel Conventional *For all refrigeration equipment other than Hussmann, use conventional Btu values. DEFROST DATA Frequency Hrs OFFTIME Temp Term °F Failsafe Minutes ELECTRIC or GAS Not Recommended PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 ½*...
  • Page 2 Specialty Products R3M-F/CR3M-F R3M-F/CR3M-F Technical Data Sheet Rev A Engineering CROSS SECTION R3M/F 2 of 9...
  • Page 3 Specialty Products R3M-F/CR3M-F R3M-F/CR3M-F Technical Data Sheet Engineering CROSS SECTION CR3M/F Rev A 3 of 9...
  • Page 4 Engineering Plan View R3 - 2002 Meat Specialty Products R3M-F/CR3M-F 24VAC Solenoids 4 of 9 R3M-F/CR3M-F Technical Data Sheet Rev A W0180016 W0180017 W0180018 W0180020 1H10019...
  • Page 5 Specialty Products R3M-F/CR3M-F R3M-F/CR3M-F Technical Data Sheet Rev A 5 of 9...
  • Page 6 Specialty Products R3M-F/CR3M-F R3M-F/CR3M-F Technical Data Sheet Rev A 6 of 9...
  • Page 7 Specialty Products R3M-F/CR3M-F R3M-F/CR3M-F Technical Data Sheet Rev A 7 of 9...
  • Page 8 Specialty Products R3M-F/CR3M-F R3M-F/CR3M-F Technical Data Sheet Rev A 8 of 9...
  • Page 9 Specialty Products R3M-F/CR3M-F R3M-F/CR3M-F Technical Data Sheet Rev A 9 of 9...

This manual is also suitable for:

Specialty products r3m-f