Outside Finish
Installation (non-Cool Wall)—Mantel Clearances
Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the Diagram below.
Mantel Clearances
14
12
10
8
6
12"
24
7"
B
12
C
0
Inches
A
To Floor
Mantel Clearances
G800EC
From Top of Fireplace
Opening
Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour.
**The non combustible board supplied with the appliance is 11 1/2" (292 mm) high. This may be cut to size if desired.
Outside Finish
Installation (non-Cool Wall)—Mantel Leg Clearances
32-1/2" (826mm)
Overall Fireplace width
4
2
Combustible
1"
Non-Combustible Material
Min. 10" H (254mm)
D
9"
Top of
Fireplace
A
B
34"
19"
(754mm)
(483mm)
(381mm)
TopView
(38mm)
Side opening
4-1/4"
of fireplace
(108mm)
6-7/8" (175mm)
Allowable mantel leg projection
C
D
15"
10"
(254mm)
1-1/2"
3"
(76mm)
Grandview® G800EC Gas Fireplace | P. 14