Servicing The Fuses - Toro Z Master Commercial 3000 Series Operator's Manual

With 52in or 72in turbo force side discharge mowe
Hide thumbs Also See for Z Master Commercial 3000 Series:
Table of Contents

Advertisement

important to prevent battery damage when the
temperature is below 0°C (32°F).
1.
Charge battery for 10 to 15 minutes at 25 to 30
A or 30 minutes at 10 A.
2.
When the battery is fully charged, unplug
the charger from the electrical outlet, then
disconnect the charger leads from the battery
posts
(Figure
55).
3.
Install the battery in the machine and connect
the battery cables; refer to
(page
42).
Note:
Do not run the machine with the battery
disconnected; electrical damage may occur.
Figure 55
1. Positive battery post
2. Negative battery post

Servicing the Fuses

The electrical system is protected by fuses. However,
it requires no maintenance. If a fuse blows, check the
component and circuit for a malfunction or short.
The fuses are located on right console next to the
seat
(Figure
56).
1.
To replace the fuses, pull out the fuse to remove
it.
2.
Install a new fuse
Installing the Battery
3. Red (+) charger lead
4. Black (-) charger lead
(Figure
56).
1. Optional accesory (15 A)
2. Charge (25 A)
3. PTO (10 A)
g000960
43
Figure 56
4. Main (25 A)
5. Console
g008966

Hide quick links: