Siemens SIMATIC Panel PC IL 77 Operating Instructions Manual page 94

Hide thumbs Also See for SIMATIC Panel PC IL 77:
Table of Contents

Advertisement

Maintenance and servicing
10.2 Installing and removing hardware components
• Check the switch settings (1). Ensure that the switch is set to match the settings in the
following table.
Figure 10-16 Separating the control unit from the computer unit, switch settings and connections
Table 10-1
Switch
3
ON
ON
ON
ON
ON
• Insert the ribbon cable through the aperature underneath the computer unit.
10-24
Switch settings for the various control units
Display type
4
5
6
ON
ON
ON
12" touch/key panel
ON
ON
OFF
15" touch/key panel
ON
OFF
ON
19" touch panel
ON
OFF
OFF
OFF
ON
ON
Resolution
Ribbon cable socket
800 x 600
X400
1024 x 768
X400
1280 x 1024
X400, X410