Technical data
13.1 Specifications
13.1.3
Ambient and environmental conditions
EMC
Electromagnetic compatibility
(EMC)
Mechanical conditions
Vibration load during operation
Shock load during operation
Climatic ambient conditions
Temperature limits
Operation
Storage/transport
Relative humidity limits
Operation
Storage/transport
Temperature change
Condensation
Supply air
13-4
EN 61000-6-4/EN 55022, EN 61000-6-2 /
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
10 to 58 Hz: 0.0007 in, 58 to 200 Hz: 0.01 oz
1 g, 30 ms, 3 shocks
5° C... 45° C
-20° F... 60° C
5 ... 80 % at 25° C
5 ... 95 % at 25° C (+77° F)
Maximum 10 K/h
Not permissible
No corrosive gases
Tested according to
IEC 60068-2-6
IEC 60068-2-27
IEC 60068-2-1
IEC 60068-2-14
IEC 60068-2-30
IEC 60068-2-56
Operating Instructions, Edition 10/2004, A5E00339979-01