Adding distilled water
(Maintenance type battery only)
64L062
" 1 Low
2 O.K.
1. Remove the vent plugs.
2. Add distilled water to cells needing fluid.
If the side of your battery is covered, check the water level by looking
down directly above the cell as illustrated above.
3. Retighten the vent plugs securely.
NOTICE
D Do not overfill the cells. Excess electrolyte could squirt out
of the battery during heavy charging, causing corrosion or
damage.
D Use a cover on the battery for longer life.
ELECTRICAL COMPONENTS
BATTERY RECHARGING
PRECAUTIONS
During recharging, the battery is producing hydrogen gas.
Therefore, before recharging:
1. Maintenance type batteries – Remove the vent plugs.
2. If recharging with the battery installed on the vehicle, be sure to
disconnect the ground cable.
3. Make sure the power switch on the recharger is off when
connecting the charger cables to the battery and when disconnecting
them.
CAUTION
D Always charge the battery in an unconfined area. Do not
charge the battery in a garage or closed room where there
is not sufficient ventilation.
D Non–maintenance batteries: Only do a slow charge (5 A or
less). Charging at a quicker rate is dangerous. The battery
may explode causing personal injuries.
Maintenance type batteries: Be sure to remove the vent
plugs before recharging.