Viessmann VITODENS 200-W B2HA Installation And Service Instructions Manual page 91

Wall mounted gas condensing boiler
Hide thumbs Also See for VITODENS 200-W B2HA:
Table of Contents

Advertisement

Fault codes
(cont.)
Fault code
Const.
displayed
Cd
X
CF
d6
X
d7
X
d8
X
dA
db
dC
dd
dE
dF
E0
E1
X
Weather-
System characteris-
comp.
tics
X
Control mode
X
Control mode
X
Control mode
X
Control mode
X
Control mode
X
Control mode without
room influence
X
Control mode without
room influence
X
Control mode without
room influence
X
Control mode without
room influence
X
Control mode without
room influence
X
Control mode without
room influence
X
Control mode
X
Burner in a fault state Ionisation current
Cause
Measures
Communication er-
Check connections,
ror, Vitocom 100,
Vitocom 100, type GSM
type GSM
and coding address "95"
in the "General"/1 group
Communication er-
Replace LON communi-
ror, LON communi-
cation module
cation module
Input DE1 at EA1
Remove fault at appliance
extension reports a
concerned
fault
Input DE2 at EA1
Remove fault at appliance
extension reports a
concerned
fault
Input DE3 at EA1
Remove fault at appliance
extension reports a
concerned
fault
Short circuit, room
Check room temperature
temperature sen-
sensor, heating circuit 1
sor, heating circuit
1 (without mixer)
Short circuit, room
Check room temperature
temperature sen-
sensor, heating circuit 2
sor, heating circuit
2 (with mixer)
Short circuit, room
Check room temperature
temperature sen-
sensor, heating circuit 3
sor, heating circuit
3 (with mixer)
Lead break, room
Check room temperature
temperature sen-
sensor, heating circuit 1
sor, heating circuit
and remote control set-
1 (without mixer)
tings (see page 110)
Lead break, room
Check room temperature
temperature sen-
sensor, heating circuit 2
sor, heating circuit
and remote control set-
2 (with mixer)
tings (see page 110)
Lead break, room
Check room temperature
temperature sen-
sensor, heating circuit 3
sor, heating circuit
and remote control set-
3 (with mixer)
tings (see page 110)
External LON sub-
Check connections and
scriber error
LON subscribers
Check gap between ioni-
too high during cal-
sation electrode and burn-
ibration
er gauze assembly (see
page 44).
In open flue operation,
prevent high levels of dust
in the combustion air.
Press reset button R.
Troubleshooting
91

Advertisement

Table of Contents
loading

Table of Contents