Viessmann VITODENS 200-W B2HA Installation And Service Instructions Manual page 62

Wall mounted gas condensing boiler
Hide thumbs Also See for VITODENS 200-W B2HA:
Table of Contents

Advertisement

Code 1
Heating circuit 1, heating circuit 2, heating...
Coding in the delivered condition
Start temperature raising
F8:-5
Temperature limit for terminating
reduced mode -5 °C; see example
on page 109.
Observe setting for coding address
"A3". (Only for weather-compensa-
ted control units)
End temperature raising
F9:-14
Temperature limit for raising the re-
duced set room temp. -14 °C; see
example on page 109. (only for
weather-compensated control
units)
Set flow temperature increase
FA:20
The set boiler water or flow tem-
perature is raised by 20 % when
changing from operation with re-
duced room temperature to opera-
tion with standard room tempera-
ture. See example on page 109
(only for weather-compensated
control units).
Duration set flow temperature increase
Fb:60
Duration for raising the set boiler
water temperature or set flow tem-
perature (see coding address "FA")
is 60 min. See example on
page 109 (only for weather-com-
pensated control units).
62
(cont.)
Possible change
F8:+10
Temperature limit adjustable from
to
+10 to -60 °C
F8:-60
F8:-61
Function disabled
F9:+10
Temperature limit for raising the set
to
room temperature to the value se-
F9:-60
lected for standard mode adjustable
from
+10 to -60 °C
FA:0
Temperature rise adjustable from 0
to
to 50 %
FA:50
Fb:0
Duration adjustable from 0 to 240
to
min
Fb:240