IBM Power System Series Problem Analysis, System Parts, And Locations page 44

Hide thumbs Also See for Power System Series:
Table of Contents

Advertisement

Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
• P1-DIMMA1 Func (0x10)
• P1-DIMMA2 Func (0x11)
• P1-DIMMB1 Func (0x12)
• P1-DIMMB2 Func (0x13)
• P1-DIMMC1 Func (0x14)
• P1-DIMMC2 Func (0x15)
• P1-DIMMD1 Func (0x16)
• P1-DIMMD2 Func (0x17)
• P2-DIMMA1 Func (0x18)
• P2-DIMMA2 Func (0x19)
• P2-DIMMB1 Func (0x1A)
• P2-DIMMB2 Func (0x1B)
• P2-DIMMC1 Func (0x1C)
• P2-DIMMC2 Func (0x1D)
• P2-DIMMD1 Func (0x1E)
• P2-DIMMD2 Func (0x1F)
30 Power Systems: Problem analysis, system parts, and locations for the 5104-22C, 9006-12P, 9006-22C, and
9006-22P
Event description
• Memory Device Disabled
• Uncorrectable Memory Error
• Memory Scrub Failed
• State Deasserted
• Device Disabled
• Transition to Critical from Less
Severe
• Transition to Non-recoverable
from Less Severe
• Transition to Critical from Non-
recoverable
• Correctable Memory Error
• Parity
• Correctable Memory Error
Logging Limit Reached
• Memory Automatically
Throttled
• Critical Over temperature
• Presence Detected
• Spare
• State Asserted
• Device Enabled
• Transition to OK
• Transition to Non-Critical from
OK
• Transition to Non-Critical from
More Severe
• Monitor
• Informational
• Transition to Non-recoverable
• Predictive Failure
Service action
No service action is required.
If the sensor name is P1-
DIMMA1 Func, replace P1-
DIMMA1. If the sensor name is
P1-DIMMA2 Func, replace P1-
DIMMA2. And so on. Go to
"5104-22C or 9006-22C
locations" on page 63,
"9006-12P locations" on page
75, or "9006-22P locations" on
page 91 to identify the physical
location and removal and
replacement procedure.