IBM Power System Series Manual

IBM Power System Series Manual

Managing pcie adapters for the machine types 9008, 9009, 9040, 9080, 9223, and the emx0 pcie3 expansion drawer
Hide thumbs Also See for Power System Series:
Table of Contents

Advertisement

Power Systems
Managing Pcie Adapters for the Machine
Types 9008, 9009, 9040, 9080, 9223,
and the EMX0 PCIe3 expansion drawer
IBM

Advertisement

Table of Contents
loading

Summary of Contents for IBM Power System Series

  • Page 1 Power Systems Managing PCIe adapters for the Machine Types 9008, 9009, 9040, 9080, 9223, and the EMX0 PCIe3 expansion drawer...
  • Page 2 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 219, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
  • Page 3 PCI Express.............................1 Partitioning with multi-adapter configurations..................2 Handling static-sensitive devices......................2 PCIe adapters for IBM Power Systems servers..................3 Managing PCIe adapters for the 9008-22L, 9009-22A, or 9223-22H system........3 Managing PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H system........4 Managing PCIe adapters for the 9040-MR9 system................
  • Page 5 Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
  • Page 6 – For racks with a DC power distribution panel (PDP), connect the customer’s DC power source to the PDP. Ensure that the proper polarity is used when attaching the DC power and DC power return wiring. • Connect any equipment that will be attached to this product to properly wired outlets. •...
  • Page 7 • Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). •...
  • Page 8 CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during relocation. Follow these general guidelines whenever you relocate a populated rack cabinet within a room or building. • Reduce the weight of the rack cabinet by removing equipment starting at the top of the rack cabinet.
  • Page 9 DANGER: Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack-mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). Stability hazard: •...
  • Page 10 DANGER: Multiple power cords. The product might be equipped with multiple AC power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) (L007) CAUTION: A hot surface nearby. (L007) x Power Systems: Managing PCIe adapters...
  • Page 11 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 12 • LIFT TOOL intended for use to assist, lift, install, remove units (load) up into rack elevations. It is not to be used loaded transporting over major ramps nor as a replacement for such designated tools like pallet jacks, walkies, fork trucks and such related relocation practices. When this is not practicable, specially trained persons or services must be used (for instance, riggers or movers).
  • Page 13 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 14 xiv Power Systems: Managing PCIe adapters...
  • Page 15 System L922 (9008-22L), IBM Power System S922 (9009-22A), IBM Power System H922 (9223-22H), IBM Power System S914 (9009-41A), IBM Power System S924 (9009-42A), or IBM Power System H924 (9223-42H), and EMX0 PCIe Gen3 I/O expansion drawer. Overview of managing PCIe adapters ®...
  • Page 16 This feature is typically referred to as Multi-Path I/O (MPIO). MPIO support is part of the operating system support and can be used to provide a redundant IBM SAS RAID controller configuration with RAID protected disks.
  • Page 17 Managing PCIe adapters for the 9008-22L, 9009-22A, or 9223-22H system Find information about using and managing the Peripheral Component Interconnect Express (PCIe) adapters for the IBM Power System L922 (9008-22L), IBM Power System S922 (9009-22A), or IBM Power System H922 (9223-22H) system. Also, find information about specifications and installation notes for specific adapters.
  • Page 18 Find information about using and managing the Peripheral Component Interconnect Express (PCIe) adapters that are supported for the IBM Power System S914 (9009-41A), IBM Power System S924 (9009-42A), or IBM Power System H924 (9223-42H) system. Also, find information about specifications and installation notes for specific adapters.
  • Page 19 • Where applicable, show special installation or cabling instructions • Show signal names for the output-pins of the adapter connectors • Where applicable, show the settings for switches or jumpers Adapters can be identified by their feature code (FC) or their custom-card identification number (CCIN). Normally, the CCIN number is labeled on the adapter.
  • Page 20 Managing PCIe adapters for the 9040-MR9 system Find information about using and managing the Peripheral Component Interconnect Express (PCIe) adapters that are supported for the IBM Power System E950 (9040-MR9) server. Also, find information about specifications and installation notes for specific adapters.
  • Page 21 verify that the CCIN is the same. If the CCIN is same, the adapter has the same function and can be used in the same way. Adapters must be placed in specific PCI Express (PCIe) slots to function correctly or optimally. SAS RAID adapters and controllers used for internal storage features in the 9040-MR9 system Find information about PCIe3 SAS RAID adapters and controllers that are installed and supported for internal storage features in the system.
  • Page 22 Table 7. SAS RAID controllers supported for the 9040-MR9 system (continued) Feature Code Description Function EJBB Storage backplane that uses a The base function storage configuration includes: PCIe3 SAS RAID quad port 6 Gb • One FC EJ0K adapter installed in C12 slot x8 adapter for SAS bays in the system unit •...
  • Page 23 • SAS RAID controllers for IBM i • SAS RAID controllers for Linux • SAS subsystem for the 9040-MR9 Managing PCIe adapters for the 9080-M9S system Find information about using and managing the Peripheral Component Interconnect Express (PCIe) adapters that are supported for the 9080-M9S system. Also, find information about specifications and installation notes for specific adapters.
  • Page 24 For more information about the PCIe3 SAS RAID controllers, see the following topics: • SAS RAID controllers for AIX • SAS RAID controllers for IBM i • SAS RAID controllers for Linux • SAS subsystem for the 9040-MR9...
  • Page 25 • If you are installing a new feature, ensure that you have the software required to support the new feature and determine whether you must install any existing program temporary fix (PTF) prerequisites. To do this, use the Power Systems Prerequisites website (www14.software.ibm.com/support/ customercare/iprt/home).
  • Page 26 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code 5260 PCIe2 4- 9008-22L 9009-22 9080- port 1 (FC EL4M) A and 9223-22 adapter...
  • Page 27 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code 5277 4-port 9008-22L 9009-22 9080- Async A and EIA-232 9223-22 PCIe 1X adapter...
  • Page 28 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code 5748 POWER 9009-41 9009-42 9040- EMX0 GXT145 A and 9223-42 Express Graphics...
  • Page 29 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC2M PCIe3 2- 9008-22L 9009-22 9080- port 10 (EL40) A and GbE NIC 9223-22...
  • Page 30 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC2R PCIe3 2- 9008-22L 9009-22 9080- port 10 A and Gb NIC &...
  • Page 31 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC2U PCIe3 2- 9009-41 9009-42 9040- EMX0 port A and 25/10 Gb 9223-42 NIC &...
  • Page 32 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC3A PCIe3 LP 9008-22L 9009-22 9080- 2-Port 40 A and GbE NIC 9223-22 RoCE...
  • Page 33 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC3F PCIe3 2- 9009-41 9009-42 port 100 A and Gb EDR 9223-42 InfiniBan...
  • Page 34 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC3T PCIe3 1- 9008-22L 9009-22 9080- port 100 A and Gb EDR 9223-22 InfiniBan...
  • Page 35 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC46 PCIe2 4- 9009-41 9009-42 9040- EMX0 port USB A and 9223-42 adapter...
  • Page 36 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC5B PCIe3 x8 9009-41 9009-42 9040- Non- A and Volatile 9223-42 Memory...
  • Page 37 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC5D PCIe3 x8 9009-41 9009-42 9040- Non- A and Volatile 9223-42 Memory...
  • Page 38 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC5F PCIe3 x8 9009-41 9009-42 9040- Non- A and Volatile 9223-42 Memory...
  • Page 39 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC62 PCIe4 9008-22L 9009-22 9080- x16 1- A and Port EDR 9223-22 100 GB...
  • Page 40 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC64 PCIe4 9008-22L 9009-22 x16 2- A and port EDR 9223-22 100 GB InfiniBan...
  • Page 41 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC66 PCIe4 9009-41 9009-42 9040- x16, 2- A and port 100 9223-42 GB RoCE...
  • Page 42 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC6U PCIe3 x8 9080- Non- Volatile Memory 1.6 TB NVMe adapter (FC EC5A,...
  • Page 43 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC6W PCIe3 x8 9080- Non- Volatile Memory 3.2 TB NVMe adapter (FC EC5C,...
  • Page 44 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EC6Y PCIe3 x8 9080- Non- Volatile Memory 6.4 TB NVMe adapter (FC EC5E,...
  • Page 45 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EJ05 PCIe3 9008-22L 9009-22 cable adapter for the EMX0 PCIe Gen3 I/O expansio...
  • Page 46 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EJ0J PCIe3 9009-41 9009-42 9040- EMX0 SAS RAID A and (FC EJ0J quad-port 9223-42...
  • Page 47 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EJ0M PCIe3 9008-22L 9009-22 9080- SAS RAID (FC EL3B) A and quad-port 9223-22...
  • Page 48 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EJ14 PCIe3 12 9009-41 9009-42 9040- EMX0 GB Cache A and RAID 9223-42...
  • Page 49 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EJ1D and PCIe3 x8 9009-41 9009-42 EJ1M cache A and SAS RAID 9223-42 internal...
  • Page 50 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EJ1G PCIe3 x8 9008-22L 9009-22 cache (FC EL67) A and SAS RAID 9223-22 Internal...
  • Page 51 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EJ1R PCIe3 9008-22L 9009-22 cable A and adapter 9223-22 for the EMX0 PCIe...
  • Page 52 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EJ28 PCIe 9040- EMX0 Crypto- graphic Coproces sor (FC EJ27 and EJ28;...
  • Page 53 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN0A PCIe3 16 9009-41 9009-42 9040- EMX0 Gb 2-port A and (FC EL5B Fibre...
  • Page 54 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN0G PCIe2 9009-41 9009-42 9040- EMX0 8Gb 2- A and Port Fibre 9223-42 Channel...
  • Page 55 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN0K PCIe3 4- 9009-41 9009-42 9040- EMX0 port (10 A and Gb FCoE 9223-42...
  • Page 56 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN0M PCIe3 4- 9040- EMX0 port (10 Gb FCoE and 1 GbE) LR and RJ45...
  • Page 57 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN0T PCIe2 LP 9008-22L 9009-22 9080- 4-port A and (10 Gb + 9223-22 1 GbE) SR...
  • Page 58 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN0W PCIe2 2- 9009-41 9009-42 9040- EMX0 port 10 A and 9223-42 BaseT...
  • Page 59 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN0Y PCIe2 LP 9008-22L 9009-22 9080- 8 Gb 4- A and port Fibre 9223-22...
  • Page 60 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN15 PCIe3 4- 9009-41 9009-42 9040- EMX0 port 10 A and GbE SR 9223-42...
  • Page 61 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN18 PCIe3 9080- LPX 4- port 10 GbE SFP+ copper adapter (FC EN17...
  • Page 62 Table 10. PCIe adapters supported in the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (continued) Feature Descripti Supported on the following systems code EN1C PCIe3 8x 9009-41 9009-42 9040- EMX0 4-port A and Fibre 9223-42 Channel...
  • Page 63 Reference information for managing PCIe adapters Learn how to install operating system device driver software, verify device driver software, and how to manage adapter battery packs. Installing the AIX device driver software Find information about how to install the AIX device driver software for a PCI adapter. Before you begin If you are installing the AIX operating system at this time, install the adapter before you install the operating system.
  • Page 64 Find information about using and managing the Peripheral Component Interconnect Express (PCIe) adapters that are supported for the IBM Power System L922 (9008-22L), IBM Power System S922 (9009-22A), or IBM Power System H922 (9223-22H), and EMX0 PCIe Gen3 I/O expansion drawer. Also, find information about specifications and installation notes for specific adapters.
  • Page 65 Australia and New Zealand. 2894 and EN14 is the CIM (Complex Impedance Matching) version offered only in Australia and New Zealand. Note: FC EN13 and EN14 are only supported with the IBM i operating system. Figure 2. PCIe Binary Synchronous Adapter Specifications...
  • Page 66 • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html). • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html).
  • Page 67 • Supports dual port operation in almost any PCIe slot, except x1 • Supports auto-negotiation, full-duplex only • Supports integrated media-access control (MAC) and physical layer (PHY) • Supports Fast EtherChannel (FEC) with the existing software • Supports gigabit EtherChannel (GEC) with the existing software •...
  • Page 68 Adapter FRU number 74Y4064 (Designed to comply with RoHS requirement) Wrap plug 10N7405 Note: Wrap plugs are not included with the card and cannot be purchased from IBM. I/O bus architecture PCIe2 x4 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/...
  • Page 69 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 70 PCIe POWER GXT145 graphics accelerator adapter (FC 5269; CCIN 5269) Learn about the features, requirements, installation notes, and troubleshooting tips for the PCIe POWER GXT145 graphics accelerator adapter. Overview The PCIe POWER GXT145 graphics accelerator adapter is a versatile 2D graphics accelerator and enhances the system unit video.
  • Page 71 Installing the adapter For instructions about installing PCIe adapters, see Installing, removing, or replacing PCIe adapters (http://www.ibm.com/support/knowledgecenter/POWER9/p9hak/pciadpters.htm) and select the system you are working on. Verifying the adapter installation To verify that your system unit recognizes the PCI adapter, do the following steps: 1.
  • Page 72 5.2.0.105 COMMITTED GXT145 Graphics Adapter If the POWER GXT145 device driver did not fully install, reinstall the driver. For instructions, see Installing the AIX device driver software (www.ibm.com/support/knowledgecenter/POWER9/p9hak/ pxhak_installing_devicedriver_aix.htm). Checking the console 1. If you continue to experience problems, you can redirect the monitor to the new adapter using the chdisp command.
  • Page 73 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 74 Figure 6. PCIe 8 Gb 2-Port Fibre Channel adapter (FC 5273 and FC EL2N) 60 Power Systems: Managing PCIe adapters...
  • Page 75 10N9824 (Designed to comply with RoHS requirement). Wrap plug FRU number 12R9314 Note: The wrap plug is included with the card, and can also be purchased from IBM. I/O bus architecture PCI Express (PCIe) Base and Card Electromechanical (CEM) 2.0 x8 PCIe bus interface.
  • Page 76 Form factor The FC 5273 and FC EL2N are short, low-profile adapters; the FC 5735 and FC EL58 are short, full- height adapters. FC compatibility 2, 4, 8 Gigabit. Cables Cables are the responsibility of the customer. Use multimode fiber optic cables with shortwave lasers that adhere to the following specifications: •...
  • Page 77 Table 15. POST conditions and results Green LED Yellow LED State Action to be taken Wake-up failure (dead Perform AIX, IBM i, or Linux operating system board) diagnostics procedure. POST failure (dead board) Perform AIX, IBM i, or Linux operating system diagnostics procedure.
  • Page 78 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 79 Figure 8. PCIe 4-port Async EIA-232 1X adapter Managing PCIe adapters 65...
  • Page 80 I/O bus architecture PCIe-V1.0a 1x Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Busmaster Adapter size PCIe 1x, short form-factor...
  • Page 81 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 82 74Y3467 (Designed to comply with RoHS requirement) Wrap plug FRU number 12R9314 Note: The wrap plug is included with the card, and can also be purchased from IBM. I/O bus architecture PCI Express (PCIe) Base 2.0 and x8 PCIe bus interface...
  • Page 83 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V Form factor Full-height, full-length adapter with standard-size bracket...
  • Page 84 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 85 POWER GXT145 PCI Express Graphics Accelerator (FC 5748; CCIN 5269) Learn about the features, requirements, installation notes, and troubleshooting tips for the POWER GXT145 PCI Express Graphics Accelerator adapter. Overview The POWER GXT145 PCI Express Graphics Accelerator adapter is a PCI Express (PCIe) adapter that accelerates and enhances the system unit video.
  • Page 86 Installing the adapter For instructions about installing PCIe adapters, see Installing, removing, or replacing PCIe adapters (http://www.ibm.com/support/knowledgecenter/POWER9/p9hak/pciadpters.htm) and select the system you are working on.. Verifying the adapter installation To verify that your system unit recognizes the PCI adapter, do the following steps: 1.
  • Page 87 5.2.0.105 COMMITTED GXT145 Graphics Adapter If the POWER GXT145 device driver did not fully install, reinstall the driver. For instructions, see Installing the AIX device driver software (www.ibm.com/support/knowledgecenter/POWER9/p9hak/ pxhak_installing_devicedriver_aix.htm). Checking the console 1. If you continue to experience problems, you can redirect the monitor to the new adapter using the chdisp command.
  • Page 88 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 89 – 802.3x for flow control – 802.3ad for load-balancing and failover – IEEE 802.3ad and 802.3 for link aggregation • The adapter provides message signal interrupts (MSI), MSI-X, and support of legacy pin interrupts. • The adapter supports jumbo frames up to 9.6 KB. •...
  • Page 90 Low-profile tailstock: 00RX872 I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V Form factor...
  • Page 91 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 92 Figure 14. PCIe3 LP 2-port 10 Gb NIC & RoCE SR/Cu Adapter (FC EC2R) 78 Power Systems: Managing PCIe adapters...
  • Page 93 I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V, 12 V Managing PCIe adapters 79...
  • Page 94 RDMA over Converged Ethernet (RoCE) Dual port 10 Gb Ethernet network connectivity Supports 10 Gb Ethernet SFP+ connectivity ® Supports 10 Gb SFP+ SR connectivity with a 10 Gb optical transceiver (IBM P/N 77P9336, purchased separately) ® Network Installation Management (NIM) support PCI Express 3.0 (up to 8 GT/s) x8...
  • Page 95 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 96 Figure 16. PCIe3 LP 2-port 25/10 Gb NIC & RoCE SFP28 Adapter (FC EC2T) 82 Power Systems: Managing PCIe adapters...
  • Page 97 I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V, 12 V. Managing PCIe adapters 83...
  • Page 98 Dual port 25 Gb/10 Gb Ethernet network connectivity. Supports 25 Gb Ethernet SFP28 connectivity. Supports 10 Gb Ethernet SFP+ connectivity. ® Supports 25 Gb SFP28 SR connectivity with a 25 Gb optical transceiver (IBM P/N 77P5153, purchased separately). ® Supports 10 Gb SFP+ SR connectivity with a 10 Gb optical transceiver (IBM P/N 77P9336, purchased separately).
  • Page 99 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 100 • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html). PCIe3 2-port 10 GbE NIC & RoCE SFP+ copper adapter (FC EC37, FC EC38, FC EL3X, and FC EL53; CCIN 57BC) Learn about the specifications and operating system requirements for the feature code (FC) EC37, FC EC38, FC EL3X, and FC EL53 adapters.
  • Page 101 Figure 18. PCIe3 LP 2-port 10 GbE NIC & RoCE SFP+ copper adapter (FC EC37 and FC EL3X) Managing PCIe adapters 87...
  • Page 102 Low-profile tailstock: 00RX856 I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V Form factor...
  • Page 103 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 104 • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html). PCIe3 2-port 40 GbE NIC RoCE QSFP+ adapter (FC EC3A and FC EC3B; CCIN 57BD) Learn about the specifications and operating system requirements for the feature code (FC) EC3A and FC EC3B adapters.
  • Page 105 Figure 21. PCIe3 LP 2-port 40 GbE NIC RoCE QSFP+ adapter (FC EC3A) Managing PCIe adapters 91...
  • Page 106 00FW105 (Designed to comply with RoHS requirement) I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V Form factor...
  • Page 107 Do not mix copper and optical cables on the same adapter. These cables are compliant with industry standard specifications SFF-8431 Rev 4.1 and SFF-8472 Rev 10.4, and all applicable IBM requirements. Note: These cables are EMC Class A compliant. Figure 23. Top and bottom view of the cable Table 26.
  • Page 108 • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html). • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html).
  • Page 109 00WT075 (Designed to comply with RoHS requirement.) I/O bus architecture PCIe3 x16 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V Form factor...
  • Page 110 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 111 00WT078 (Designed to comply with RoHS requirement.) I/O bus architecture PCIe3 x16 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V Form factor...
  • Page 112 See FC EB2B, EB2H, and ECBN for a 1 M, 3 M, and 5 M copper cables. Transceivers IBM qualifies and supports QSFP28 optical transceiver (FC EB59) to install into the adapter. Customers can also use their own optical cabling and QSP28 optical transceiver for the other end.
  • Page 113 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 114 00WT013 (Designed to comply with RoHS requirement) I/O bus architecture PCIe3 x16 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V Form factor...
  • Page 115 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 116 The following table shows the feature code, custom card identification number, and field-replaceable unit part number for the adapter. Table 27. Adapter feature code, CCIN, and FRU part number Custom card identification Field-replaceable unit (FRU) Feature code (FC) number (CCIN) part number EC42 00E3980...
  • Page 117 IBM Installation Toolkit for PowerLinux. Managing PCIe adapters 103...
  • Page 118 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 119 • The adapter supports the simultaneous operation of multiple USB 3.0, USB 2.0, and USB 1.1 devices. Restriction: When multiple keyboards are attached to the USB ports on the system or on the USB adapter, only one keyboard can be used while the partition is booting-up. •...
  • Page 120 I/O bus architecture PCIe 2.2 compliant Slot priority For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Busmaster Form factor FC EC45: Short form factor, half-length...
  • Page 121 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 122 I/O bus architecture PCIe2.1 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Supported Systems POWER9 processor-based systems 108 Power Systems: Managing PCIe adapters...
  • Page 123 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 124 • A single PCIe3 2x4 NVMe M.2 internal carrier adapter can be installed in the internal PCIe3 x8 slot (P1- C49) in supported systems. It can also be installed in the other internal PCIe3 x8 slot (P1-C50) if the PCIe3 x8 SAS RAID internal adapter 6 Gb (FC EJ1C) is installed in slot P1-C49. •...
  • Page 125 FC EC5A, EC5B, EC5G, EC6U, and EC6V are all the same adapters with different feature codes. FC EC5A, EC5G, and EC6U are low-profile adapters. FC EC5B and EC6V are full-height adapters. FC EC5A, EC5B, and EC5G are supported on AIX or Linux operating systems. FC EC6U and EC6V are supported on IBM i operating system.
  • Page 126 I/O bus architecture PCIe3 x8. Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V, 12 V. 112 Power Systems: Managing PCIe adapters...
  • Page 127 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 128 I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. 114 Power Systems: Managing PCIe adapters...
  • Page 129 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 130 IBM warranty or maintenance. This adapter has protection against single Flash channel failures. To prevent the entire adapter from failing, software RAID should be used. For high-value applications where the content in the adapter must be protected, additional NVMe Flash adapters with OS mirroring or software Redundant Array of Independent Disks (RAID) are recommended.
  • Page 131 • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the NVMe management tool can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/set2/sas/f/lopdiags/home.html). • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html).
  • Page 132 I/O bus architecture PCIe4 x16 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. 118 Power Systems: Managing PCIe adapters...
  • Page 133 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 134 I/O bus architecture PCIe4 x16 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. 120 Power Systems: Managing PCIe adapters...
  • Page 135 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 136 Figure 37. 2-port 100 GbE RoCE En Connectx-5 Gen4 PCIe x16 adapter (FC EC66) 122 Power Systems: Managing PCIe adapters...
  • Page 137 (CHANGE TO LINK) Cable and transceiver matrix. Note: For 40G, IBM offers DAC cables up to 3 M. QSFP+ base transceivers are included on each end of these cables. See FC EB2B and EB2H for a 1 M and 3 M copper cables.
  • Page 138 Transceivers IBM qualifies and supports QSFP28 optical transceiver (FC EB59) to install into the adapter. Customers can also use their own optical cabling and QSP28 optical transceiver for the other end. This is a 100Gbase-SR4 based active optical transceiver capable up to 100 M through the OM4 cable or 70 M through OM3 cable.
  • Page 139 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 140 adapter also supports enhanced data rate (EDR) copper and optical cables when connecting to EDR 100 Gb or HDR 200 Gb InfiniBand switches. See “Cable matrix” on page 127 for more details. Note: The Virtual Protocol Interconnect (VPI) feature is not supported on this adapter. The adapter must be used only as an InfiniBand adapter.
  • Page 141 GTH, or 8335-GTX system. Cables For HDR 100 Gb, IBM offers either Direct Attach Copper (DAC) cables up to 2 M or Active Optical Cables (AOC) up to 100 M. QSFP56 based transceivers are included on each end of these cables.
  • Page 142 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 143 supports enhanced data rate (EDR) copper and optical cables when connecting to EDR 100 Gb or HDR 200 Gb InfiniBand switches. See “Cable matrix” on page 130 for more details. Note: The Virtual Protocol Interconnect (VPI) feature is not supported on this adapter. The adapter must be used only as an InfiniBand adapter.
  • Page 144 GTH, or 8335-GTX system. Cables For HDR 100 Gb, IBM offers either Direct Attach Copper (DAC) cables up to 2 M or Active Optical Cables (AOC) up to 100 M. QSFP56 based transceivers are included on each end of these cables.
  • Page 145 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 146 000RR809 (Designed to comply with RoHS requirement). I/O bus architecture PCIe3 x16 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 12 V Form factor...
  • Page 147 PCIe3 cable adapter (FC EJ07; CCIN 6B52) Learn about the specifications and operating system requirements for the feature code (FC) EJ07 adapter. Overview The FC EJ07 is a double-wide, low-profile, PCIe generation 3 (PCIe3) cable adapter. The adapter provides two optical ports for the attachment of two expansion drawer cables. One adapter supports the attachment of one PCIe3 6-slot fanout module in a EMX0 PCIe Gen3 I/O expansion drawer.
  • Page 148 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 12 V Form factor Full-height, full-length PCIe3 cable adapter (FC EJ08; CCIN 2CE2) Learn about the specifications and operating system requirements for the feature code (FC) EJ08 adapter.
  • Page 149 AIX, IBM i, and Linux partitions. This adapter enables configuring the SAS drives as dedicated hot-spares with equal or higher capacity. Important: See the SAS RAID controllers for AIX, SAS RAID controllers for IBM i, or SAS RAID controllers for Linux topics for more information and important considerations for multi-initiator and high availability...
  • Page 150 Figure 44 on page 136 shows the adapter. The connector plug (A) is installed in an empty port and prevents damage to that port whenever a cable for the adjacent port connectors is plugged-in or removed. Figure 44. PCIe3 SAS RAID adapter Specifications Item Description...
  • Page 151 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 152 The adapter provides both single and dual RAID controller configurations. The exception to this is when installed in PCIe slots C09 and/or C012 of the IBM Power System E950 (9040-MR9), the adapter will only run in single controller mode. In dual controller configurations (dual storage IOA) all attached devices must run RAID.
  • Page 153 Figure 45. PCIe3 RAID SAS adapter Specifications Item Description Adapter FRU number 02DE906 (Designed to comply with Restriction of Hazardous Substances (RoHS) requirement.) Connector plug part number 00FW784 (The connector plug is installed in an empty port and prevents damage to that port whenever a cable for the adjacent port connectors is plugged-in or removed.) I/O bus architecture PCIe 3.0 but compatible to PCIe 2.0 or PCIe 1.0 slots.
  • Page 154 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 155 PCIe3 12 GB Cache RAID SAS quad-port 6 Gb Adapter (FC EJ0L; CCIN 57CE) Learn about the specifications and operating system requirements for the feature code (FC) EJ0L adapters. Overview The PCI Express (PCIe) generation 3, 12 GB Cache RAID SAS quad-port 6 Gb Adapter is a large cache PCIe3 SAS adapter that provides high-performance capabilities and supports the attachment of serial- attached SCSI (SAS) disks and SAS solid-state drives (SSDs) through four mini SAS high-density (HD) connectors.
  • Page 156 Systems running the AIX or Linux operating systems support either having both EJ0L features in the same system or partition, or in two separate systems or partitions. Systems running the IBM i operating system do not support the pairing of adapters on different servers or different partitions, so both the EJ0L...
  • Page 157 HDDs in the AIX or Linux systems. Important: See the SAS RAID controllers for AIX, SAS RAID controllers for IBM i, or SAS RAID controllers for Linux topics for more information and important considerations for multi-initiator and high availability...
  • Page 158 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 159 PCIe 3.0 but compatible to PCIe 2.0 or PCIe 1.0 slots. Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V...
  • Page 160 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 161 Externally attached devices are designed to run at a maximum data rate of 6 Gbps for SAS tape devices. Important: See the SAS RAID controllers for AIX, SAS RAID controllers for IBM i, or SAS RAID controllers for Linux topics for more information and important considerations for multi-initiator and high availability or dual storage IOA configurations Figure 48 on page 147 and Figure 49 on page 148 show the adapters.
  • Page 162 Figure 49. PCIe3 4 x8 SAS port adapter (FC EL65 and FC EJ10) Specifications Item Description Adapter FRU number 000MH959 (Designed to comply with RoHS requirement). Connector plug part number 00FW784 (The connector plug is installed in an empty port and prevents damage to that port whenever a cable for the adjacent port connectors is plugged-in or removed.) I/O bus architecture PCIe 3.0 but compatible to PCIe 2.0 or PCIe 1.0 slots.
  • Page 163 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 164 The adapter provides RAID 0, RAID 5, RAID 6, RAID 10, RAID 5T2, RAID 6T2, RAID 10T2, and OS mirroring (LVM) for the AIX, Linux, and VIOS operating systems. Under the IBM i operating system, the adapter provides RAID 5, RAID 6, OS mirroring, and data spreading. RAID 10 is supported by IBM i Version 7.2 or later.
  • Page 165 Figure 50. PCIe3 12 GB Cache RAID + SAS 6 Gb Adapter Specifications Item Description Adapter FRU number 01DH742 (Designed to comply with RoHS requirement) Connector plug part number 00FW784 (The connector plug is installed in an empty port and prevents damage to that port whenever a cable for the adjacent port connectors is plugged-in or removed) I/O bus architecture PCIe 3.0 (compatible with 2.0 and 1.0)
  • Page 166 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 167 02AE929 (Designed to comply with RoHS requirement). I/O bus architecture PCIe3 x16 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 12 V Form factor...
  • Page 168 PCIe3 x8 SAS RAID internal adapter 6 Gb (FC EJ1C and FC EJ1E; CCIN 57D7) Learn about the specifications and operating system requirements for the PCIe3 x8 SAS RAID internal adapter 6Gb (CCIN 57D7) that is integrated with the storage backplane (FC EJ1C) in the 9009-41A, 9009-42A, or 9223-42H.
  • Page 169 For information about operating system and partition requirements, see one of the following topics: • The latest version of enabling libraries and utilities can be downloaded from Fix Central (http:// www.ibm.com/support/fixcentral/). • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). Managing PCIe adapters 155...
  • Page 170 • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html). • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html).
  • Page 171 SSDs and cold data to attached HDDs in the AIX or Linux systems. Systems running the IBM i operating system do not support the two adapters being owned by different partitions, nor the Easy Tier function.
  • Page 172 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 173 6 Gb to the two SAS ports on the storage backplane. This configuration with one PCIe3 x8 SAS RAID internal adapter 6 Gb does not split the disks in the storage backplane. Two adapters split storage backplane configuration To enable the split storage backplane, another PCIe3 x8 SAS RAID internal adapter 6 Gb (FC EJ1H or FC EL68) must be installed in the other dedicated internal PCIe3 x8 slot P1-C50.
  • Page 174 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 175 One mini-SAS HD cable connects the PCIe3 x8 cache SAS RAID internal adapter 6 Gb to the SAS port on the internal storage backplane. For more information, see Front SAS cable.The expanded function internal adapter supports both types of SFF drives (HDDs and SSDs). The supported RAID configurations include: RAID 0, 5, 6, 10, 5T2, 6T2, and 10T2 depending on the operating system support.
  • Page 176 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 177 PCIe1 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Cables SAS device attachment requires specific cables that are provided with the subsystem or device features being attached.
  • Page 178 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 179 02AE884 (Designed to comply with RoHS requirement). I/O bus architecture PCIe3 x16 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 12 V Form factor...
  • Page 180 PCIe3 cable adapter (FC EJ20; CCIN 2CF5) Learn about the specifications and operating system requirements for the feature code (FC) EJ20 adapter. Overview FC EJ20 is a full-height, half-length PCIe3 cable adapter. The adapter provides two optical ports for the attachment of two expansion drawer cables.
  • Page 181 • FC EJ27 is not a blind-swap cassette • FC EJ28 is a generation-3 blind-swap cassette IBM PCIe Cryptographic adapter highlights: • PCIe 4x standard height - half length • Integrated Dual PPC processors •...
  • Page 182 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 183 • The loss of battery power or a voltage drop triggers a tamper event and permanently renders the coprocessor inoperable. • Any short on the battery power distribution circuits causes a voltage drop and a tamper event. • Do not lay the coprocessor on or cause the coprocessor to come in contact with any conductive surface.
  • Page 184 Figure 59. 4767-002 Cryptographic Coprocessor Specifications Item Description Adapter FRU number Not applicable I/O bus architecture PCIe1 x4 170 Power Systems: Managing PCIe adapters...
  • Page 185 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 186 To install and or update the Linux drivers and firmware, the user must download the Power Systems Linux drivers and firmware package. Refer to the IBM Power Systems information on the 4767-002 Cryptographic Coprocessor and follow the Linux drivers and firmware instructions at: Power Systems Information for the 4767-002 Cryptographic Coprocessor (https://www-03.ibm.com/security/...
  • Page 187 – Provides a maximum Fibre Channel throughput that is achieved by using full duplex hardware support • The adapter provides an end-to-end data path parity and CRC protection, including internal data path random-access memory (RAM) • Provides architectural support for multiple upper layer protocols •...
  • Page 188 Figure 60. PCIe3 16 Gb 2-port Fibre Channel adapter (FC EL43 and EN0B) 174 Power Systems: Managing PCIe adapters...
  • Page 189 00E3496 (Designed to comply with RoHS requirement) Wrap plug FRU number 12R9314 Note: The wrap plug is included with the card, and can also be purchased from IBM. I/O bus architecture PCIe base and CEM 3.0, x8 PCIe bus interface...
  • Page 190 FC compatibility 4, 8, 16 Gb Cables Cables are the responsibility of the customer. Use multimode fiber optic cables with shortwave lasers that adhere to the following specifications: • OM4: Multimode 50/125 micron fiber, 4700 MHz x km bandwidth • OM3: Multimode 50/125 micron fiber, 2000 MHz x km bandwidth •...
  • Page 191 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 192 PCIe2 8 Gb 2-port Fibre Channel adapter (FC EL5Y, FC EL5Z, FC EN0F, and FC EN0G; CCIN 578D) Learn about the specifications and operating system requirements for feature codes (FC) EL5Y, FC EL5Z, FC EN0F, and FC EN0G adapters. Overview FC EL5Y and FC EN0F is a low-profile adapter and FC EL5Z and FC EN0G is a full-height adapter.
  • Page 193 Short, with full-height tailstock (FC EL5Z and FC EN0G) Maximum number For details about the maximum number of adapters that are supported, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Attributes provided...
  • Page 194 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 195 PCIe3 4-port (2x10 Gb FCoE, 2x1 GbE) SFP+ adapter (FC EL38, FC EL56, FC EN0H, and FC EN0J; CCIN 2B93) Learn about the specifications and operating system requirements for the feature code (FC) EL38, FC EL56, FC EN0H, and FC EN0J adapters. Overview The FC EL38 and FC EN0J are low-profile adapters.
  • Page 196 Figure 63. PCIe3 4-port (2x10 Gb FCoE, 2x1 GbE) SFP+ full-hight adapter (FC EL56 and FC EN0H) 182 Power Systems: Managing PCIe adapters...
  • Page 197 12R9314 (for Fibre LC connector). 10N7405 (for RJ45 connector). Note: These wrap plugs are not included with the card. 12R9314 (FC ECW0) is the only wrap plug that can be purchased from IBM. I/O bus architecture PCIe3 x8. Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/...
  • Page 198 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 199 • The adapter supports all Fibre Channel and Ethernet topologies. • The 10 Gb SFP+ ports can function in the NIC or FCoE mode. • The adapter supports the SR-IOV (Single Root I/O Virtualization) NIC capability. • The adapter can function as a Boot adapter. Figure 65.
  • Page 200 Wrap plug FRU number 74Y7010 10N7405 Note: These wrap plugs are not included with the card. 12R9314 (FC ECW0) is the only wrap plug that can be purchased from IBM. I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/...
  • Page 201 See Figure 67 on page 187 for a view of the cable top and cable bottom. These cables are compliant with industry standard specifications SFF-8431 Rev 4.1 and SFF-8472 Rev 10.4, and all applicable IBM requirements. Note: These cables are EMC Class A compliant.
  • Page 202 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 203 Wrap plug FRU number 74Y7010 10N7405 Note: These wrap plugs are not included with the card. 12R9314 (FC ECW0) is the only wrap plug that can be purchased from IBM. I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/...
  • Page 204 See Figure 69 on page 190 for a view of the cable top and cable bottom. These cables are compliant with industry standard specifications SFF-8431 Rev 4.1 and SFF-8472 Rev 10.4, and all applicable IBM requirements. Note: These cables are EMC Class A compliant.
  • Page 205 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 206 Figure 70. PCIe3 4-port (10 Gb FCoE and 1 GbE) LR and RJ45 adapter (FC EN0M) 192 Power Systems: Managing PCIe adapters...
  • Page 207 Wrap plug FRU number 12R9314 (for Fibre LC connector) 10N7405 Note: These wrap plugs are not included with the card. 12R9314 (FC ECW0) is the only wrap plug that can be purchased from IBM. I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/...
  • Page 208 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 209 connectors. The optical transceiver uses shortwave laser optics and is attached with MMF-850nm fiber cabling with LC connectors. See “Cables” on page 198 for more information about the optical cables. Each 10 Gb port provides Ethernet connectivity with a nominal data rate of 10 Gbps (gigabits per second). Figure 72 on page 196 shows the FC EN0S and FC EN0U adapter.
  • Page 210 Figure 72. PCIe2 4-Port (10 Gb + 1 GbE) SR / Copper SFP +RJ45 adapter (FC EN0S and FC EN0U) Note: The ports are numbered from top to bottom as T1, T2, and so on for the AIX and IBM i operating systems.
  • Page 211 Figure 73. PCIe2 LP 4-port (10Gb+1GbE) SR / Copper SFP +RJ45 adapter (FC EN0T and FC EN0V) Note: The ports are numbered from top to bottom of the adapter as T1, T2, and so on for the AIX and IBM i operating systems.
  • Page 212 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 213 PCIe2 2-port 10 GbE BaseT RJ45 adapter (FC EL3Z, FC EL55, FC EN0W, and FC EN0X; CCIN 2CC4) Learn about the specifications and operating system requirements for the feature code (FC) EL3Z, FC EL55, FC EN0W, or FC EN0X adapter. Overview The PCIe2 2-port 10 GbE BaseT RJ45 adapter is a PCI Express (PCIe) generation 2, x8 adapter.
  • Page 214 Figure 74. PCIe2 2-port 10 GbE BaseT RJ45 adapter (FC EL55 or FC EN0W) Figure 75. PCIe2 LP 2-port 10 GbE BaseT RJ45 adapter (FC EL3Z or FC EN0X) 200 Power Systems: Managing PCIe adapters...
  • Page 215 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 216 logical (virtual) connections to share the same physical port. Each logical connection has its own resources and the ability to be managed independently. Each port provides single initiator capability over a fiber link or provides multiple initiator capability with N_Port ID Virtualization (NPIV). The ports are connected by using mini little connectors (mini-LC) type connectors.
  • Page 217 Adapter FRU number 74Y3923 (Designed to comply with RoHS requirement) Wrap plug FRU number 12R9314 Note: The wrap plug is included with the card, and can also be purchased from IBM. I/O bus architecture PCIe2.0 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/...
  • Page 218 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 219 I/O bus architecture PCIe2.0 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V, 12 V Managing PCIe adapters 205...
  • Page 220 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 221 PCIe3 4-port 10 GbE SR Adapter (FC EN15 and FC EN16; CCIN 2CE3) Learn about the specifications and operating system requirements for the feature code (FC) EN15 and EN16 adapter. Overview The FC EN15 and EN16 are the same adapter. FC EN15 is a full-height adapter, and FC EN16 is a low- profile adapter.
  • Page 222 00ND466 (Designed to comply with RoHS requirement) Full-height tailstock part number: 00ND462 Wrap plug FRU number 12R9314 (SFP+ SR wrap plug) Note: The wrap plug is not included with the card, but can be purchased from IBM. I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/...
  • Page 223 For information about operating system and partition requirements, see one of the following topics: • The latest version of enabling libraries and utilities can be downloaded from Fix Central (http:// www.ibm.com/support/fixcentral/). • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). Managing PCIe adapters 209...
  • Page 224 • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html). • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html).
  • Page 225 74Y7010 (Twinax wrap plug) I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Managing PCIe adapters 211...
  • Page 226 See Figure 80 on page 212 for a view of the cable top and cable bottom. These cables are compliant with industry standard specifications SFF-8431 Rev 4.1 and SFF-8472 Rev 10.4, and all applicable IBM requirements. Note: These cables are EMC Class A compliant.
  • Page 227 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 228 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 229 I/O bus architecture PCIe3 x16. Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on.. Voltage 3.3 V, 12 V. Form factor Short, low-profile.
  • Page 230 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 231 01FT699 (Designed to comply with RoHS requirement) 12R9314 I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Managing PCIe adapters 217...
  • Page 232 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 233 Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 234 This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 235 Contact the vendor for accessibility information about its products. Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 236 Electronic emission notices Class A Notices The following Class A statements apply to the IBM servers that contain the POWER9 processor and its features unless designated as electromagnetic compatibility (EMC) Class B in the feature information. When attaching a monitor to the equipment, you must use the designated monitor cable and any interference suppression devices supplied with the monitor.
  • Page 237 Tel: 914-499-1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Relations Europe, Abteilung M456 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A.
  • Page 238 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 239 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 240 IBM Deutschland GmbH Technical Relations Europe, Abteilung M456 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55032 Klasse B Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase.
  • Page 241 Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 242 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed.
  • Page 244 IBM®...

Table of Contents