a. Ensure that a problem does not exist with the connection to the network location.
b. Ensure that the adapter has a valid IP address for the network.
c. Replace the network adapter.
• If your system is a 5104-22C or 9006-22C, go to "5104-22C or 9006-22C locations" on page
63 to identify the physical location and the removal and replacement procedure.
• If your system is a 9006-12P, go to "9006-12P locations" on page 75 to identify the physical
location and the removal and replacement procedure.
• If your system is a 9006-22P, go to "9006-22P locations" on page 91 to identify the physical
location and the removal and replacement procedure.
4. Petitboot displays all recognized bootable images to use by default. Is the boot image recognized by
Petitboot?
If
Yes:
No:
5. To determine the command to type on the Petitboot command line to verify that the boot drive is
recognized and in optimal status, use Table 1 on page 8.
Table 1. Determine the command to verify that the boot drive is recognized and in optimal status
Boot drive configuration
Virtual drive connected directly to the system
backplane
Physical drive connected directly to the system
backplane
Is the boot drive recognized and in optimal status?
If
Yes:
No:
6. Are the drives properly seated in their respective drive bays?
Note:
• If your system is a 5104-22C or 9006-22C, go to "5104-22C or 9006-22C locations" on page 63
to identify the physical location and the removal and replacement procedure.
• If your system is a 9006-12P, go to "9006-12P locations" on page 75 to identify the physical
location and the removal and replacement procedure.
• If your system is a 9006-22P, go to "9006-22P locations" on page 91 to identify the physical
location and the removal and replacement procedure.
If
Yes:
No:
7. Refresh the Petitboot boot options. Is the boot image on the boot drive recognized?
If
Yes:
No:
8 Power Systems: Problem analysis, system parts, and locations for the 5104-22C, 9006-12P, 9006-22C, and
9006-22P
Then
Continue with step "10" on page 9.
Select the Petitboot menu option to refresh the boot images. If the problem persists,
continue with the next step.
Then
Reinstall the operating system on the boot drive. This ends the procedure.
Continue with the next step.
Then
Continue with the next step.
Properly seat the drives in the drive bays. Then, go to step "4" on page 8.
Then
Boot the operating system. Then, continue with step "10" on page 9.
Continue with the next step.
Commands
arcconf getconfig 1 LD
arcconf getconfig 1 PD