IBM 3745 Series Connection And Integration Manual page 92

Communication controller/nways multiprotocol controller
Table of Contents

Advertisement

o
o
o
-ITU-T ·interface type:
- V.24
- V.35··
- X.21.
• The ARC is connected to either a OTE or OCE.
• The cables are available in a range of cable lengths (for further
details of available cable lengths, refer to the Migration and
Planning Guide, GA33-0183).
Figure 3-21 shows the different types of ARC cable connectors.
ARC Assembly
B
V.24
V.35
X.21
IBM 3745
Figure
3-21. The ARC Assembly 8 and Its Different Types of Connector
o
Select the ARC cable that has a label that corresponds to the line
o
needs:
• ITU-T interface type
• Destination (OTE or DCE)
• Length.
Step 10
Label an ARC cable
a. Verify that the following information about each ARC from the
plugging sheets is on a pair of ARC cable labels (part number
63F2505):
• LCB:
- Number
- Location
• IBM 3746-900 name
• Range of the L1C 11 addresses.
• Connector slot position (+0 to +14 or + 16 to +30)
• Symbolic line name.
Chapter 3. 3746-900: Installing LCBs and ARCs, Connecting Cables