Run Command Input Selection: b1-02

This section explains how to assign the run command input.
Parameters b1-01 and b1-02 can be used to select the source of the run command and the
frequency reference independently, e.g. set the reference from the operator and set the run
command from the terminals.
WARNING! Sudden Movement Hazard. When the run command is given by turning on the power to the drive,
the motor will begin rotating as soon as the drive is powered up. Be sure to take proper precautions if using
this setting. Ensure the area around the motor is safe. Failure to comply could result in death or serious injury.
n
Run the Drive at 6 Hz using the LED Operator: b1-02 = 0
To assign the run command to the operator panel, set parameter b1-02 to "0". This will set up
the drive to acknowledge the run command through the LED operator. Initialize the run
command using the Run and Stop keys. Upon power up, the drive uses parameter b1-02 to
determine the run command location.
The following procedure indicates how to start and stop the drive through the LED operator
after parameter b1-02 has been set to 0.
Note:
When b1-02 (Run Command Selection) is not set to 0 (operator), press
1. Turn on the power to the drive. The initial display appears.
Set the frequency reference to F6.00 (6 Hz).
2.
Note:Refer to Drive Mode Details on page 80
to set the frequency reference.
3.
Press the
key to start the motor.
4. The motor should accelerate up to 6 Hz while the RUN light is on.
STOP
5. Press the
key to stop the motor. The RUN light will flash
until the motor comes to a complete stop.
n
Run the Drive using Digital Input Terminals: b1-02 = 1
This setting uses the digital input terminals to enter the run command. The factory setting is
a 2-wire sequence.
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
Step
for instructions on how
4.5 Basic Operation
to set LOCAL.
Display/Result
STOP
off
on
flashing
off
4
89