4.5 Basic Operation
Single-Phase 200 V
Carrier
Model
Frequency
(Capacity)
(kHz)
2
BA0003
0.75 kW/
10
0.4 kW
15
2
BA0006
1.1 kW/
10
0.75 kW
15
—
—
—
—
2
BA0010
2.2 kW/
8
1.5W
15
—
—
—
—
—
—
u
Multi-Step Speed Operation (4-Step Speed)
Select up to 9 preset references (including Jog reference) using two multi-function inputs S4
and S5. Two multi-step references can be selected using two multi-function inputs as
illustrated in
Figure
n
Multi-Step Speed Operation Parameters
No.
Name
d1-01 Frequency Reference 1
d1-02 Frequency Reference 2
d1-03 Frequency Reference 3
96
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
Three-Phase 200 V
Output
Model
Current
(Capacity)
(A)
3.3
2A0004
3.0
0.75 kW/
0.4 kW
2.4
6.0
5.0
—
4.0
2A0006
—
1.1 kW/
0.75W
2A0008
—
1.5 kW/
1.1 kW
9.6
2A0010
8.0
2.2 kW/
1.5W
6.4
2A0012
—
3.0 kW/
2.2 kW
2A0018
—
3.7 kW/
3.0W
2A0020
—
5.5 kW/
4.0 kW
4.14.
Frequency reference. o1-03 determines the units, with Hz as the default.
Frequency reference when multi-function input "Multi-Step Speed Reference
1" (H1-oo = 3) is on. Setting unit: set by o1-03.
Frequency reference when multi-function input "Multi-Step Speed Reference
2" (H1-oo = 4) is on. Setting unit: set by o1-03.
Carrier
Output
Frequency
Current
(kHz)
(A)
2
3.3
10
3.0
15
2.4
—
—
2
6.0
10
5.0
15
4.0
2
8.0
8
6.9
15
5.5
2
9.6
8
8.0
15
6.4
2
12.0
8
11.0
15
8.8
2
17.5
8
14.0
15
11.2
2
19.6
8
17.5
15
14.0
Description
Three-Phase 400 V
Carrier
Model
Frequency
(Capacity)
(kHz)
2
4A0002
0.75 kW/
8
0.4 kW
15
2
4A0004
1.5 kW/
8
0.75 kW
15
—
—
—
—
2
4A0005
2.2 kW/
8
1.5W
15
2
4A0007
3.0 kW/
8
2.2 kW
15
2
4A0009
3.7 kW/
8
3.0 kW
15
2
4A0011
5.5 kW/
8
4.0 kW
15
Output
Current
(A)
2.1
1.8
1.1
4.1
3.4
2.0
—
—
5.4
4.8
2.9
6.9
5.5
3.3
8.8
7.2
4.3
11.1
9.2
5.5