SECTION ONE: GENERAL SAFETY INSTRUCTIONS

GAS AND ELECTRICAL REQUIREMENTS AND GROUNDING INSTRUCTIONS
PLEASE READ CAREFULLY
Dual-Fuel Models:
PD304
120/240 volts, 60 Hz.,
35 Amp electrical circuit required.
Dual-Fuel Models:
PD364GD, PD364GL,
PD366
120/240 volts, 60 Hz.,
40 Amp electrical circuit required.
Dual-Fuel Models:
PD486GD, PD486GL,
PD484GG
120/240 volts, 60 Hz.,
50 Amp electrical circuit required.
ALWAYS DISCONNECT THE
ELECTRICAL PLUG FROM THE
WALL RECEPTACLE BEFORE
SERVICING THIS UNIT.
It is recommended that a
dedicated circuit servicing this
appliance be provided.
The use of gas cooking appliances
results in the production of heat
and moisture.

Safety Precautions

!
FOR PERSONAL SAFETY,
THIS APPLIANCE MUST BE
CONNECTED TO A
PROPERLY GROUNDED
AND POLARIZED
ELECTRICAL POWER
SUPPLY.
See Installation Instructions for electrical requirements and
grounding instructions.
It is the personal responsibility and obligation of you, the user, to have
this appliance connected to the electrical power supply in accordance
with the National Electrical Code and/or applicable local codes and
ordinances by a qualified electrician.
If for any reason a gas control knob is turned ON and there is no electric
power to operate the electronic igniters on the cooktop burners, turn
OFF the gas control knob and wait 5 minutes for the gas to dissipate
before lighting the cooktop burner manually.
To light the cooktop burners manually, carefully hold a lighted match to
the burner ports and turn the gas control knob to HI. During a power
failure you can use the cooktop burners, but each must be lit with a match.
DO NOT attempt to light the two left burners manually. These burners are
equipped with the ExtraLow
TESTED IN ACCORDANCE
WITH:
• ANSI Z21.1 Current Issue for
Household Gas Appliances
• UL858 Current Edition for
Household Electric Ranges.
SAVE THESE INSTRUCTIONS
CAUTION - ALL MODELS
IN CASE OF AN ELECTRICAL FAILURE
®
feature and cannot be lit manually.
3
CAUTION
Accessible parts may be-
come hot when the grill is
in use. Young children must
be kept away.
Check your local building codes
for the proper method of
installation. In the absence of
local codes, this unit should be
installed in accordance with the
National Fuel Gas Code No.
Z223.1/NFPA54-current Issue
and the National Electrical Code
ANSI/NFPA/70-current issue.

Advertisement