Unpacking A Device - Siemens 7XV545 Product Information

Communication converters
Table of Contents

Advertisement

Available languages

Available languages

Product Information
Communication Converters

Unpacking a Device

Devices are tested prior to delivery. Devices are packed on site in a way that meets the requirements of standard ISO 2248.
Check the packing for external transport damage. Damaged packing may indicate that the devices inside have also sustained damage.
Unpack devices carefully; do not use force.
Visually check the devices to ensure that they are in perfect mechanical condition.
Check the enclosed accessories against the delivery note to make sure that everything is complete.
Keep the packing in case the devices must be stored or transported elsewhere.
If the device is damaged, return damaged devices to the manufacturer, stating the defect. Use the original packaging or transport packaging that
meets the requirements of standard ISO 2248.
NOTE
Before commissioning the device, leave it in the final operating room
for at least 2 hours. This allows it to reach room temperature and to
prevent dampness and condensation.
Mounting
General Information
The device should be mounted in a dry, dirt free location.
Field Wires of Control Circuits shall be separated from other circuits with respect to the end use requirements!
The permitted ambient temperature must be observed (see technical data). Operating the device outside the permitted operating temperature
range can lead to function errors and device failure.
The terminals are designed for conductor cross-sections of 2.5 mm² max. (AWG 14).
Ensure that no direct sunlight, no condensation and no high temperature changes takes place during operation.
The above mounting instructions must be performed correctly to provide sufficient protection against touching live parts.
Commissioning
Check that the operational data match the rated data on the label and the technical data of the device. This applies in particular to the supply
voltage and to the maximum values of alternating current and alternating voltage.
Connect all cables to the terminals as described in the manual.
Turn on all attached accessory devices and the device's supply voltage.
NOTE
The device does not have a power on/off switch. Switch on/off the
device's supply voltage by a suitable disconnecting device.
Operation
Manuals
Please read the manuals and other information notes on your product.
Repair
CAUTION
Danger of damage due to static electrical charges
The user is not authorized to repair the device when it is defective. This
is because the device contains special electronic components that may
only be handled by the manufacturer in compliance with the regulations
for electrostatic sensitive devices (ESD).
Furthermore, hazardous voltages can lead to lethal injuries when the
work is performed improperly.
If you suspect that the device has a defect, Siemens recommends to
send the entire device back to the manufacturer. If possible, use the
original transport packaging or an equivalent packaging.