Control i/o terminals rs-232c protocol specifications
Hide thumbs Also See for CD-01U:

Advertisement

5-28. ERROR SENSE RETURN
Transmitted in response to an ERROR SENSE command [78], giving the specific error that has
occurred.
Command
Data
Request command ERROR SENSE [78]
Data 1
N2
Data 2
N3
Data 3
0
Data 4
N1
*** Your unit must be version V1.02 for these commands to be supported.
(for update instructions please visit www.tascam.com)
TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
F8
4 bytes
Error code( N1-N2N3)
26
1-01
TOC Read Error
1-02
GFS Error
1-03
Focus servo Error
1-04
Sub Q Reading Error
1-05
Disk loading Error
1-06
Sled Error
1-10
SDRAM check Error
1-13
System Error
TEAC Corporation