Download Print this page

Tascam CD-01U Specifications page 19

Control i/o terminals rs-232c protocol specifications
Hide thumbs Also See for CD-01U:

Advertisement

5-4. PITCH CONTROL DATA RETURN
Transmitted in response to a PITCH CONTROL DATA PRESET command [25] with the request data
([FF]) to show the currently set Pitch Control value.
Command
Data
Request command PITCH CONTROL DATA PRESET [25]
Data 1
Data 2
N2
N3
5-5. FADE IN/OUT TIME RETURN
Transmitted in response to a FADE IN/OUT TIME PRESET command [2E] with the request data ([00FF]
or [01FF]) to show the currently set the Fade In and Out time.
Command
Data
Request command FADE IN/OUT TIME PRESET [2E]
Data 1
Data 2
Data 3
0
0
Tens digit of Fade In time
0
1
Tens digit of Fade Out time
5-6. AUTO CUE SELECT RETURN
Transmitted in response to an AUTO CUE SELECT command [30] with the request data ([FF]) to show
the currently set the Auto Cue mode status .
Command
Data
Request command AUTO CUE SELECT [30]
Data 1
Data 2
Description
0
0
Auto Cue Off
0
1
Auto Cue On
5-7. EOM TRACK TIME RETURN
Transmitted in response to an EOM TRACK TIME PRESET command [32] with the request data ([FF])
to show the currently set EOM time.
Command
Data
Request command EOM TRACK TIME PRESET [32]
Data 1
Data 2
Description
N1
N2
Sec
TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
A5
4 bytes
Data 3
Data 4
Description
0
1
N1
Preset %
AE
4 bytes
B0
2 bytes
Remarks
Auto Cue function is turned off
Auto Cue function is turned on
B2
2 bytes
19
Remarks
Positive (+) value
Negative (-) value
N1: Tens digit of pitch control value
N2: Units digit of pitch control value
st
N3: 1
decimal of pitch control value
Sample) 2310: -2.3%
Data 4
Units digit of Fade In time
Units digit of Fade Out time
Remarks
N1: Tens digit of EOM time
N2: Units digit of EOM time
00=Off
Remarks
Fade In time
Fade Out time
TEAC Corporation

Advertisement

loading

This manual is also suitable for:

Cd-01upro