Download Print this page

Tascam CD-01U Specifications page 15

Control i/o terminals rs-232c protocol specifications
Hide thumbs Also See for CD-01U:

Advertisement

4-23. TIME DATA SEND SELECT
Sets the Time mode of the time data that is sent out from the controlled device automatically (without
any request command).
When this command is transmitted with request data [FF], the controlled device returns the TIME DATA
SEND SELECT RETURN command [BF].
When specified data includes "Without Frame" information, frame information will not shown on the
display of the controlled device.
Command
Data
Return
Data 1
Data 2
Description
0
0
Off
0
1
Elapsed Time
0
2
Remain Time
0
4
Total Remain Time
1
1
Elapsed Time
1
2
Remain Time
1
4
Total Remain Time
F
F
Time Data Send status request
· If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
4-24. PLAY MODE SELECT
Sets the Play mode.
The status of the PLAY mode can be requested using the PLAY MODE SENSE command [4E].
Command
Data
Return
Data 1
Data 2
Description
0
0
Normal Play
0
1
Single Play
0
2
Program Play
0
3
Random Play
· If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
4-25. PLAY MOSE SENSE
Requests the status of the Play mode.
The contents of the reply are described in the PLAY MODE RETURN command.
Command
Data
Return
4-26. MECHA STATUS SENSE
Requests the status of the mechanism.
The contents of the reply are described in the MECHA STATUS RETURN command.
Command
Data
Return
TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
3F
2 bytes
TIME DATA SEND SELECT RETURN [BF]
4D
2 bytes
None
Remarks
Sets the Play Mode to normal (continuous) play mode
Sets the Play Mode to single play mode
Sets the Play Mode to program play mode
Sets the Play Mode to random play mode
4E
None
PLAY MODE RETURN [CE]
50
None
MECHA STATSU RETURN [D0]
15
Remarks
Time data (TIME DATA [88]) will not be sent
out from the controlled device automatically
With frame data
With frame data
With frame data
Without frame data
Without frame data
Without frame data
Requests the Output Time Data status
TEAC Corporation

Advertisement

loading

This manual is also suitable for:

Cd-01upro