5-16. MECHA STATUS RETURN
Transmitted in response to a MECHA STATUS SENSE command [50] and gives the current mechanism
status of the controlled device.
Command
Data
Request command MECHA STATUS SENSE [50]
Data 1
Data 2
Description
0
0
No Disc
0
1
Eject / load
0
2
Eject
1
0
Stop
1
1
Play
1
2
Ready
5-17. ISRC RETURN
Transmitted in response to an ISRC SENSE command [53], giving the ISRC disc catalog number (stop
mode) or current track code (play or ready modes).
ISRC codes are only available from playback-only discs. If an attempt is made to read an ISRC code
from any other type of disc, the controlled device will return "0". The '0' will also be transmitted if an
attempt is made to read an ISRC code from a playback-only disc which has no such codes recorded on
it.
Command
Data
Request command ISRC SENSE [53]
Description
Data 1-12
ISRC code
Data 13-25
Catalog No.
5-18. TRACK No. RETURN
Transmitted in response to a TRACK No. SENSE command [55], giving the current track status.
Command
Data
Request command TRACK No. SENSE [55]
Description
Data 1
EOM Status
Data 2
Data 3
Tens digit of the Track Number
Data 4
Units digit of the Track Number
Data 5
Thousands digit of the Track Number
Data 6
Hundreds digit of the Track Number
TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
D0
2 bytes
Remarks
A disc is not loaded
Ejecting or Loading a disc
Ejecting a disc
Transport is in stop mode
Transport is playing
Transport is pausing
D3
25 bytes
D5
6 bytes
22
Remarks
Remarks
00: Does not show the EOM status
01: Shows the EOM status
TEAC Corporation