5. Return Command Detail
5-1. TIME DATA
When the Time mode is set to other than "OFF" with TIME DATA SEND SELECT command [3F],
controlled device outputs the time data in specified form by TIME DATA SEND SELECT command [3F].
Command
Data
Description
Data 1
Tens digit of minutes
Data 2
Units digit of minutes
Data 3
Thousands digit of minutes
Data 4
Hundreds digit of minutes
Data 5
Tens digit of seconds
Data 6
Units digit of seconds
Data 7
Tens digit of frames
Data 8
Units digit of frames
5-2. INFORMATION RETURN
Transmitted in response to an INFORMATION REQUEST command [0F].
Returns the software version of the controlled device.
Command
Data
Request command INFORMATION REQUEST [0F]
Data 1
Tens digit of software version
Data 2
Units digit of software version
st
Data 3
1
decimal digit of software version
Data 4
Hundreds digit of software version
5-3. AUTO CUE LEVEL RETURN
Transmitted in response to an AUTO CUE LEVEL PRESET command [20] with the request data ([FF])
to show the currently set Auto Cue level.
Command
Data
Request command AUTO CUE LEVEL PRESET [20]
Data 1
Data 2
Description
0
0
-24dB
0
1
-30dB
0
2
-36dB
0
3
-42dB
0
4
-48dB
0
5
-54dB
0
6
-60dB
0
7
-66dB
0
8
-72dB
TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
88
8 bytes
8F
4 bytes
A0
2 bytes
Remarks
Auto Cue detect level is set to –24dB
Auto Cue detect level is set to –30dB
Auto Cue detect level is set to –36dB
Auto Cue detect level is set to –42dB
Auto Cue detect level is set to –48dB
Auto Cue detect level is set to –54dB
Auto Cue detect level is set to –60dB
Auto Cue detect level is set to –66dB
Auto Cue detect level is set to –72dB
18
Remarks
Sample data for Data 1 - Data 4
0100
Version 1.00
TEAC Corporation