en | Installing the In-Ceiling Mount
Connector
Alarm In Connector [P103]
Analog Relay Connector [P104]
Table 7.1: Alarm and relay connector pins, Interface box
1.
2.
7.6

Interface Box Connections

The following figure is a detailed illustration of the In-ceiling Interface box.
2019-09 | 0.8 |
To connect supervised alarms and relays, attach the appropriate wires to their terminals
on the P104 connector on the Pipe Interface Board. Refer to the Connection, page 30
chapter for more details on wiring alarms.
Attach the lid to the Interface box:
Align the slots on the lid with the two posts at the rear of the Interface box.
Rotate the lid down.
Squeeze the ground clips, located at the front of the box, against the Interface box with
your fingers before closing the lid to ensure that the lid does not catch on the ground
clips.
Secure the lid to the Interface box by pushing the lid down until the clip on the lid
catches against the box.
Pin
Label
Description
1
A3
2
A4
3
A5
4
A6
5
A7
6
AGND
1
NO
2
COM
3
NC
4
5
A1
6
A2
7
AGND
Installation Manual
AUTODOME IP starlight 7000i
Wire Color
Alarm in 3
White
Alarm in 4
Brown
Alarm in 5
Orange
Alarm in 6
Green
Alarm in 7
Yellow
Alarm ground
Blue
Alarm Out 4/Relay
Normally Open
Alarm Out 4/Relay
COM
Alarm Out 4/Relay
Normally Closed
Earth Ground
Analog Alarm 1
Analog Alarm 2
Alarm ground