en | Connection
AUTODOME Programmed N.O.S.
Contact
Open
Closed
Cut or break
Configuring a Normally Closed Supervised Alarm
1.
2.
Figure 10.3: N.C.S. - Normally Closed Supervised Connections
1
2
3.
AUTODOME Programmed N.C.S.
Contact
Open
Closed
Short
Configuring Non-supervised Alarms (inputs 3 through 7)
You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally
Closed (N.C.) alarms.
Configuring a Normally Open Non-supervised Alarm
1.
Figure 10.4: N.O. - Normally Open Non-supervised Connections
1
2019-09 | 0.8 |
Alarm Condition
Normal
Alarm
Tamper
Install a 2.2 K end-of-line resistor in the alarm circuit.
Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
camera.
2.2K
Dry Contact
Alarm 1 or 2 only (Pin 5 or 6)
From Configuration, select Interfaces > Alarm Inputs, select the number of the Alarm
input and finally, select N.C. See the table below for contact and condition details.
Alarm Condition
Alarm
Normal
Tamper
Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Dry Contact
3
Installation Manual
AUTODOME IP starlight 7000i
3
Dome Connector
4
Ground (Pin 7)
Dome Connector