Compaq SLT 386s/20 Maintenance And Service Manual page 32

Table of Contents

Advertisement

1706 - xx
Fixed disk drive ready
test failed
1707 - xx
Fixed disk drive recalibrate
test failed
1708 - xx
Fixed disk format bad track
test failed
------------------------------------------------------------------------------
Error
Code
Description
------------------------------------------------------------------------------
1709 - xx
Fixed disk reset controller
test failed
1710 - xx
Fixed disk park head
test failed
1714 - xx
Fixed disk file write
test failed
1715 - xx
Fixed disk head select
test failed
1716 - xx
Fixed disk conditional
format test failed
1717 - xx
Fixed disk Error
Correction Detection
(ECC) test failed
1719 - xx
Fixed disk drive power
mode test
1719 - 01
Exceeded maximum soft
error limit
------------------------------------------------------------------------------
Error
Code
Description
------------------------------------------------------------------------------
1719 - 02
Exceeded maximum hard
error limit
1719 - 03
Previously exceeded maximum
soft error limit
1719 - 04
Previously exceeded maximum
hard error limit
1719 - 05
Failed to reset controller
1719 - 06
Fatal error while reading
1719 - 07
Fatal error while writing
1719 - 08
Failed compare of
write/read/compare
Recommended Action
The following steps apply to error
codes 1700 - xx through 1799 - xx:
1.
Replace the fixed disk drive
signal and power cables and
retest.
2.
Replace the fixed disk drive and
retest.
3.
Replace the system board and
retest.
Recommended Action
The following steps apply to error
codes 1700 - xx through 1799 - xx:
1.
Replace the fixed disk drive
signal and power cables and
retest.
2.
Replace the fixed disk drive and
retest.
3.
Replace the system board and
retest.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slt/286

Table of Contents