Input line or clock failure
1109 - 05
Address line fault
1109 - 06
Data line fault
==============================================================================
Table 3-8.
Modem Communications Test Error Codes
==============================================================================
Error
Code
Description
------------------------------------------------------------------------------
1201 - xx
Modem Internal Loopback Test
1201 - 01
UART DLAB bit failure
1201 - 02
Line input or UART failure
1201 - 03
Address line fault
1201 - 04
Data line fault
1201 - 05
UART control signal failure
1201 - 06
UART THRE bit failure
1201 - 07
UART DATA READY bit failure
1201 - 08
UART TX/RX buffer failure
1201 - 09
INTERRUPT circuit failure
1201 - 10
COM1 set to invalid interrupt
1201 - 11
COM2 set to invalid interrupt
1201 - 12
DRIVER/RECEIVER control signal
failure
------------------------------------------------------------------------------
Error
Code
Description
------------------------------------------------------------------------------
1201 - 13
UART control signal interrupt
failure
1201 - 14
DRIVER/RECEIVER data failure
1201 - 15
Modem detection failure
1201 - 16
Modem ROM; checksum failure
1201 - 17
Tone detection failure
1202 - xx
Modem Internal Test
Recommended Action
The following steps apply to error
codes 1201 - xx through 1210 - xx:
1.
Refer to the modem documentation
for SETUP procedures.
2.
Check the modem line.
3.
Replace the modem and retest.
Recommended Action
The following steps apply to error
codes 1201 - xx through 1210 - xx:
1.
Refer to the modem documentation
for SETUP procedures.
2.
Check the modem line.
3.
Replace the modem and retest.