SITRANS FX330
1.1 General notes
This additional instruction applies to explosion-protected versions of vortex flowmeters with
protection type flameproof enclosure "d", increased safety "e" and equipment dust-ignition
protection through enclosure "t", equipment category II 2 G and II 2 D, EPL Gb and EPL Db.
It completes the standard manual for the non-explosion protected versions.
The information given in this instruction contains only the data relevant to explosion protection
of category 2. The technical details given in the manual for the non-explosion protected versions
remain unchanged unless they will be excluded or replaced by this instruction.
1.2 EU conformity
The manufacturer declares with the EU declaration of conformity on his own responsibility
conformity with the protection goals of directive 2014/34/EU for use in hazardous areas with gas
and dust.
The EU declaration of conformity for the equipment category II 2 G and II 2 D is based on the EU
type examination certificate:
The "X" after the certificate number refers to special conditions for safe use of the device, which
have been listed in these instructions.
If needed the EU type examination certificate can be downloaded from the manufacturer's
website.
1.3 Approval according to the IECEx scheme
Conformity for use in hazardous areas with gas and dust was tested in accordance with the
"IECEx Certification Scheme for Explosive Atmospheres" according to
IEC 60079-0:2011, IEC 60079-1:2014, IEC 60079-7:2006, IEC 60079-11:2011 and
IEC 60079-31:2013.
The number of the IECEx certificate is:
The "X" after the certificate number refers to special conditions for safe use of the device, which
have been listed in these instructions.
If needed, the IEC certificate can be downloaded from the manufacturer's website.
09/2018 - A5E40861058-AB
SAFETY INSTRUCTIONS
KIWA 16 ATEX 0045X
KIWA 16 ATEX 0045X
KIWA 16 ATEX 0045X
KIWA 16 ATEX 0045X
IECEx KIWA 16.0022X
IECEx KIWA 16.0022X
IECEx KIWA 16.0022X
IECEx KIWA 16.0022X
www.siemens.com/flow
1
3