Siemens SITRANS F Series Additional Operating Instructions page 10

Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

DEVICE DESCRIPTION
2
INFORMATION!
The maximum permissible product temperatures listed in the tables are valid under
the following conditions:
The measuring device is installed and operated in accordance with the manufacturer's
installation instructions.
It must be ensured that the flowmeter is not heated by the effects of additional heat radiation
(sunshine, neighbouring system components) and thus operated above the permissible
ambient temperature range.
Insulation must be limited to the piping. Unobstructed ventilation of the signal converter
must be ensured.
The permitted ambient temperature range is indicated on the nameplate; depending on the
device version it is T
The minimum product temperature is -40°C / -40°F.
When using in zone 21, observe the maximum permissible product and ambient temperatures
for temperature class 2 and the information for use of a heat-resistant connecting cable and
cable entry.
10
= -40...+65°C / -40...+149°F.
amb
www.siemens.com/flow
SITRANS FX330
09/2018 - A5E40861058-AB