DEVICE DESCRIPTION
2
INFORMATION!
The maximum permissible product temperatures listed in the tables are valid under
the following conditions:
The measuring device is installed and operated in accordance with the manufacturer's
•
installation instructions.
It must be ensured that the flowmeter is not heated by the effects of additional heat radiation
•
(sunshine, neighbouring system components) and thus operated above the permissible
ambient temperature range.
Insulation must be limited to the piping. Unobstructed ventilation of the signal converter
•
must be ensured.
The permitted ambient temperature range is indicated on the nameplate; depending on the
device version it is T
The minimum product temperature is -40°C / -40°F.
When using in zone 21, observe the maximum permissible product and ambient temperatures
for temperature class 2 and the information for use of a heat-resistant connecting cable and
cable entry.
10
= -40...+65°C / -40...+149°F.
amb
www.siemens.com/flow
SITRANS FX330