Ref. No. Address
Indication Name
color
D4502
(G-9)
Green
D4503
(G-9)
Amber
D4504
(G-9)
Amber
D4505
(G-9)
Blue
D4506
(G-9)
Blue
D4507
(G-9)
Blue
D4508
(G-9)
Blue
D4509
Side B
Green
(G-9)
D7001
(H-5)
Green
D7002
(H-5)
Green
D7003
(H-5)
Green
D7004
(H-5)
Green
D7005
(H-5)
Green
D7006
(H-4)
Red
D7007
(H-4)
Red
D7008
(H-4)
Red
D7009
(H-4)
Red
D7501
(G-5)
Green
D7502
(G-5)
Green
D7503
(G-5)
Green
D7504
(G-5)
Green
D7505
(G-5)
Green
D7506
(G-4)
Red
D7507
(G-4)
Red
D7508
(G-4)
Red
D7509
(G-4)
Red
D8001
(H-3)
Red
D8002
(H-3)
Red
D8003
(H-3)
Red
D8004
(H-3)
Red
D8005
(H-3)
Red
D8006
(H-3)
Red
D8007
(H-3)
Red
D8008
(H-3)
Red
D8009
(H-3)
Red
D8010
(H-3)
Red
D8011
(J-3)
Red
D8012
(J-3)
Red
NSS-S2
RAID_FPGA__STATUS1
RAID_FPGA__STATUS2
RAID_FPGA__STATUS3
RAID_FPGA__STATUS4
RAID_FPGA__STATUS5
RAID_FPGA__STATUS6
RAID_FPGA__STATUS7
RAID_FPGA__INITDONE
SAS1064_LSI1_ACTIVITY3
SAS1064_LSI1_ACTIVITY2
SAS1064_LSI1_ACTIVITY1
SAS1064_LSI1_ACTIVITY0
SAS1064_LSI1_LIFEBEET
SAS1064_LSI1_FOULT3
SAS1064_LSI1_FOULT2
SAS1064_LSI1_FOULT1
SAS1064_LSI1_FOULT0
SAS1064_LSI2_ACTIVITY3
SAS1064_LSI2_ACTIVITY2
SAS1064_LSI2_ACTIVITY1
SAS1064_LSI2_ACTIVITY0
SAS1064_LSI2_LIFEBEET
SAS1064_LSI2_FOULT3
SAS1064_LSI2_FOULT2
SAS1064_LSI2_FOULT1
SAS1064_LSI2_FOULT0
SASX12_LSI1_FAULT11
SASX12_LSI1_FAULT10
SASX12_LSI1_FAULT9
SASX12_LSI1_FAULT8
SASX12_LSI1_FAULT7
SASX12_LSI1_FAULT6
SASX12_LSI1_FAULT5
SASX12_LSI1_FAULT4
SASX12_LSI1_FAULT3
SASX12_LSI1_FAULT2
SASX12_LSI1_FAULT1
SASX12_LSI1_FAULT0
Function
Circuit board operation status. Blinks after
the on-board MPU starts up and the ready
state is established.
For design purpose
RAID FPGA output. Lights when the RAID
FPGA configuration is complete.
Blink when Port3 to 0 on the SAS1064 LSI1
side are accessing data (send or receive).
Blinks when SAS1064 LSI1 is ready to start
operation.
Light when Port3 to 0 on the SAS1064 LSI1
side are not connected, or no link is
established.
Blink when Port3 to 0 on the SAS1064 LSI2
side are accessing data (send or receive).
Blinks when SAS1064 LSI2 is ready to start
operation.
Light when Port3 to 0 on the SAS1064 LSI2
side are not connected, or no link is
established.
Light when Port11 to 0 on the SASX12 LSI1
side are not connected, or no link is
established.
Normal state
(When connect to
the MPU-136 board)
Blinking
Lights on
Lights on
Lights off
Blinking
Lights on
Lights on
Lights off
Lights off
Lights off
Blinking
Lights off
Blinking
Blinking
Lights off
Lights off
Lights off
Lights off
Lights off
Lights off
Lights off
Lights off
Lights off
Lights on