Fault messages
(cont.)
Fault number
System characteristics
on the display
F.582
Control mode without room
influence
F.682
Burner in a fault state
F.683
Burner in a fault state
F.684
Burner in a fault state
Note
If subscriber faults occur, "Fault, subscriber ..." is dis-
played.

Repairs

!
Please note
Residual water will escape when the boiler or
one of the following components is fitted or
removed:
Water-filled pipework
Heat exchanger
Circulation pumps
Plate heat exchanger
Components fitted in the heating water or
DHW circuit.
Water ingress can result in damage to other
components.
Protect the following components against
ingress of water:
Control unit components (especially in the
service position)
Electrical components
Plug-in connections
Cables and leads

Shutting down the boiler

1. Switch OFF the power supply.
2. Shut off the gas supply.
Cause
Short circuit, room tem-
perature sensor, heating
circuit 3
Air mass flow rate sensor
not installed
Air mass flow rate sensor
faulty
Back draught safety de-
vice faulty
3. If the boiler needs to be removed:
Disconnect the balanced flue system.
Drain the boiler on the heating water and DHW
sides.
Disconnect the on-site cables/leads.
Troubleshooting
Measures
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Install the correct fan.
Reset the appliance.
Replace fan.
Reset the appliance.
Check the back draught safety de-
vice and replace if necessary.
Reset the appliance.