Chapter 2
Installing the Device
Figure 15: MX5000 and RUGGEDCOM MX5000RE Assembly
1. #10-32×1" Screw    2. #10 Split Lockwasher    3. #10 Flat Washers    4. Grounding Cable    5. #10 Exterior Tooth Lockwasher   
6. #10-32 Hex Nut    7. Power Supply Cable Assemblies    8. #6-32×3/8" SS304 Truss Head Philips Drive Screw    9. Inside Grounding
Stud
WARNING!
Crushing hazard – risk of serious injury or damage to equipment. Make sure the device is properly
supported at all times. It is highly recommended to employee the assistance of another technician.
2.
Have an assistant hold the attached cables and patch panel clear of the RUGGEDCOM MX5000RE sides.
3.
Hold the RUGGEDCOM MX5000 by both mount bracket handles and lower it into the RUGGEDCOM
MX5000RE.
4.
Lower the RUGGEDCOM MX5000 unit until the mount bracket flanges are supporting the unit on the inner
mount bracket surfaces. If the RUGGEDCOM MX5000 does not lower far enough, make sure the support pins
on the back of the mount brackets are properly aligned with the alignment holes inside the RUGGEDCOM
MX5000RE.
5.
Secure the RUGGEDCOM MX5000 to the RUGGEDCOM MX5000RE using 18 screws, flat washers and split
lockwashers. Make sure each screw is assembled with two flat washers, one split lockwasher and then the
screw.
20
8
9
Assembling the RUGGEDCOM MX5000 and RUGGEDCOM
RUGGEDCOM MX5000RE
Installation Guide
1
2
3
4
5
6
7
MX5000RE