Siemens SIMATIC NET MM900 Compact Operating Instructions

Industrial ethernet switches
Hide thumbs Also See for SIMATIC NET MM900:

Advertisement

Quick Links

SIMATIC NET
Industrial Ethernet switches
MM900 media modules for
SCALANCE XR-500M
Compact Operating Instructions
04/2022
A5E03275846-05
Introduction
Safety notes
Recommendations on
network security
Device description
installing and removing
Connecting
Service and maintenance
Technical data
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9
10

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET MM900

  • Page 1 Introduction Safety notes Recommendations on network security SIMATIC NET Device description Industrial Ethernet switches MM900 media modules for installing and removing SCALANCE XR-500M Connecting Compact Operating Instructions Service and maintenance Technical data Dimension drawings Approvals 04/2022 A5E03275846-05...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................5 Safety notes ............................7 Recommendations on network security ....................9 Device description ..........................15 installing and removing........................17 Safety notices for installation ..................... 17 Disassembly........................23 Connecting ............................25 Safety when connecting up....................25 Connecting a media module ....................
  • Page 4 Table of contents MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 5: Introduction

    You will find the SIMATIC NET glossary here: • SIMATIC NET Manual Collection or product DVD The DVD ships with certain SIMATIC NET products. • On the Internet under the following address: 50305045 (https://support.industry.siemens.com/cs/ww/en/view/50305045) MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 6 (http://www.siemens.com/industrialsecurity) Device defective If a fault develops, send the device to your SIEMENS representative for repair. Repairs on-site are not possible. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
  • Page 7: Safety Notes

    Safety notes Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury and damage, read the manual before using the device.
  • Page 8 Safety notes MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 9: Recommendations On Network Security

    OpenVPN). • Separate connections correctly (WBM, SSH etc.). • Check the user documentation of other Siemens products that are used together with the device for additional security recommendations. • Using remote logging, ensure that the system protocols are forwarded to a central logging server.
  • Page 10 Industrial Security (https://www.siemens.com/ industrialsecurity) website. • Inform yourself regularly about security recommendations published by Siemens ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm). • Only activate protocols that you require to use the device. • Restrict access to the management of the device with rules in an access control list (ACL).
  • Page 11 • Verify certificates based on the fingerprint on the server and client side to prevent "man in the middle" attacks. Use a second, secure transmission path for this. • Before sending the device to Siemens for repair, replace the current certificates and keys with temporary disposable certificates and keys, which can be destroyed when the device is returned.
  • Page 12 Recommendations on network security • The following protocols provide secure alternatives: – HTTP → HTTPS – Telnet → SSH – SNMPv1/v2c → SNMPv3 Check whether use of SNMPv1/v2c. is necessary. SNMPv1/v2c is classified as non-secure. Use the option of preventing write access. The device provides you with suitable setting options.
  • Page 13 Recommendations on network security • Configurable port – ✓ The port status can be changed. – -- The port status cannot be changed. • Authentication Specifies whether the communication partner is authenticated. • Encryption Specifies whether or not the transfer is encrypted. Protocol Protocol/ Default port status Configurable port...
  • Page 14 Recommendations on network security MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 15: Device Description

    Device description Article numbers Type Properties Article number MM991-4 4 x 100 Mbps, ST ports optical, multimode fiber-op‐ 6GK5 991-4AB00-8AA0 tic cable, up to max. 5 km. MM991-4LD 4 x 100 Mbps, ST ports optical, single mode fiber- 6GK5 991-4AC00-8AA0 optic cable, up to max.
  • Page 16 2. Check all the parts for transport damage. If the consignment is incomplete or if there is damage to the exterior, contact your supplier or your local Siemens office. Components of the product The following components are supplied with an MM900 media module: •...
  • Page 17: Installing And Removing

    installing and removing Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 40 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 40 ℃.
  • Page 18 installing and removing 5.1 Safety notices for installation WARNING The device may only be operated in an environment of contamination class 1 or 2 (see EN/IEC 60664-1, GB/T 16935.1). WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure.
  • Page 19 installing and removing 5.1 Safety notices for installation Additional notes CAUTION Use only approved components If you use components and accessories that are not approved for SIMATIC NET devices or their target systems, this may violate the requirements and regulations for safety and electromagnetic compatibility.
  • Page 20 Remove the protective caps only immediately before you use the plug-in connection. NOTICE Use only approved SFPs If you use components not approved by Siemens AG, in particular SFPs, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 21 installing and removing 5.1 Safety notices for installation You can use media modules with the following devices: • SCALANCE XR528-6M • SCALANCE XR552-12M Notes on plugging/pulling media modules NOTICE Use only approved media modules In the module slots of the devices, use only approved media modules "MM900" of the SCALANCE XR-500 IE switches product line.
  • Page 22 installing and removing 5.1 Safety notices for installation Slot Port A SCALANCE XR528-6M has a total of six slots and four SFP+ ports. Note Slot number In modular devices, the MM900 media modules can be assigned a slot number. The labels for the slot numbers ship with the modular devices.
  • Page 23: Disassembly

    installing and removing 5.2 Disassembly Pulling a media module To pull a media module, follow the same steps as when plugging, but in the reverse order: 1. Pull out the handle of the media module. 2. Pull the media module out of the device slot. 3.
  • Page 24 installing and removing 5.2 Disassembly MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 25: Connecting

    Connecting Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present.
  • Page 26 Connecting 6.1 Safety when connecting up WARNING Improper installation of shielded cables There is a risk of explosion due to equalizing currents between the hazardous area and the non- hazardous area. • Ground shielded cables that cross hazardous areas at one end only. •...
  • Page 27: Connecting A Media Module

    Connecting 6.2 Connecting a media module WARNING Suitable cables at high ambient temperatures in hazardous area If the device is operated at max. ambient temperature, only use cables with permitted maximum operating temperature of at least 90 ℃. The cable entries used on the enclosure must comply with the IP degree of protection required by EN IEC / IEC 60079-0, GB 3836.1.
  • Page 28 Connecting 6.2 Connecting a media module MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 29: Service And Maintenance

    Service and maintenance WARNING Unauthorized repair of devices in explosion-proof design Risk of explosion in hazardous areas • Repair work may only be performed by personnel authorized by Siemens. WARNING Impermissible accessories and spare parts Risk of explosion in hazardous areas •...
  • Page 30 Service and maintenance MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 31: Technical Data

    Technical data Mechanical and electrical data Device variants The following technical specifications apply to the following device: • MM900 media module for SCALANCE XR-500M Note Degree of protection of the media modules Note that the media modules do not have a degree of protection. The degree of protection is only relevant for the basic devices.
  • Page 32 Technical data 8.1 Mechanical and electrical data Media module Dimensions and weight Value MM992-4PoE Dimensions 120 x 22 x 305 mm (W x H x D) MM992-4PoEC Weight 387 g Permitted ambient conditions Environmental conditions Transportation/storage tempera‐ -40 to +70 °C ture Operating temperature 0 to +60 °C...
  • Page 33: 8.2 Cable Lengths Of The Mm900 Media Modules For Scalance Xr-500M

    Technical data 8.2 Cable lengths of the MM900 media modules for SCALANCE XR-500M Media module Transmitter output (optical) Receiver input min. [dBm] max. [dBm] Sensitivity min. [dBm] Input power max. [dBm] MM992-4SFP MM992-4PoE MM992-4PoEC MM991-4 MM991-4LD MM992-4 -9.5 MM992-4LD -9.5 Electrical data: Galvanic isolation with PoE modules Media module Electrical isolation...
  • Page 34: Other Properties

    Technical data 8.3 Other properties Permitted cable lengths (fiber-optic cable) for the SFP media module Media module Property Max. permittted cable length MM992-4SFP 4 x 100/1000 Mbps, Depending on the SFP transceiver used SFP media module Permitted cable lengths (fiber-optic cable - Fast Ethernet) Media module Property Fiber...
  • Page 35 Technical data 8.3 Other properties Device version (power supply) MTBF MM992-4SFP > 170 years MM992-4PoE > 75 years MM992-4PoEC empty MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 36 Technical data 8.3 Other properties MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 37: Dimension Drawings

    Dimension drawings View from the front, top, and side (right) Dimensions are specified in mm. MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 38 Dimension drawings MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 39: Approvals

    Note that the media modules meet the requirements of the approvals only in combination with the devices. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15318/cert). Notes for the manufacturers of machines This product is not a machine in the sense of the EC Machinery Directive or the Supply of Machinery (Safety) Regulations (UK).
  • Page 40 Importer UK: Siemens plc, Manchester M20 2UR You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/ 15273/cert). MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 41 "SIMATIC NET Product Information Use of subassemblies/modules in a Zone 2 Hazardous Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013).
  • Page 42 Approvals You will find the current versions of the standards in the currently valid certificates. Note for devices with CLASS 1 LASER Important note on products certified according to Type Examination Certificate KEMA 07ATEX0145 X as of Issue 95 / DEKRA 18ATEX0025 X and IECEx Certificate of Conformity DEK 14.0025X as of Issue 43 / DEK 18.0017X and containing Class 1 optical radiation sources.
  • Page 43 Approvals cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. complying with • UL 60950-1 (Information Technology Equipment) • CSA C22.2 No. 60950-1-03 Report no. E115352 cULus Approval Hazardous Location cULus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc.
  • Page 44 Approvals Eurasian Economic Union of Russia, Belarus, Armenia, Kazakhstan and Kyrgyzstan Declaration of conformity according to the technical regulations of the customs union (TR ZU) MSIP 요구사항 ‑ For Korea only A급 기기(업무용 방송통신기자재) 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정...
  • Page 45 • "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/27069465) • "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) • "EMC Installation Guidelines" configuration manual (https:// support.industry.siemens.com/cs/ww/en/view/60612658)
  • Page 46 Approvals MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...
  • Page 47: Index

    Index Slot number, 22 System manual, 19, 45 Approvals, 39 Article numbers, 15 CE mark, 39 Dummy cover, 22 Factory settings, 21 Glossary, 5 Handle, 22 Media module, 21 Modular device, 21 Module slot, 21 Power supply Media modules, 27 Safety notices for installation, 17 general, 7...
  • Page 48 Index MM900 media modules for SCALANCE XR-500M Compact Operating Instructions, 04/2022, A5E03275846-05...

Table of Contents