S55 Specifications

This chapter contains these major sections:

• Chassis Physical Design

Agency Compliance
Chassis Physical Design
Parameter
Height
Width
Depth
Chassis weight with factory-installed components
Rack clearance required
Thermal Dissipation
Power Consumption

Environmental Parameters

Parameter
Temperature
Maximum altitude
Relative humidity
Shock

AC Power Requirements

Parameter
Nominal Input Voltage
Maximum AC Power Supply Input Current
Maximum System Power Input
Specifications
32° to 104°F (0° to 40°C)
-40° to 158°F (-40° to 70°C)
No performance degradation to 10,000 feet (3,048 meters)
10 to 85% non-condensing
MIL-STD-810
Specifications
1.73 inches (4.4 cm)
17.32 inches (44.0 cm)
18.74 inches (47.6cm)
14.41 pounds (approx.) (6.54 kg)
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
461 BTU/hr (135W)
115 Watts (nominal)
135 Watts (maximum)
Specifications
100 to 240 VAC, 47-63 Hz
5 A
135 W