VERIFY Function

This function compares the constants stored in the Digital Operator with
the constant in the Inverter. Verification is possible only for the Invert-
ers with same product series and power supply specifications.
When the constants stored in the Digital Operator are the same as those
in the Inverter, vFy will flash, and then End will be displayed.
Example: Comparing Constants Stored in EEPROM in Operator with
Constants in Inverter
Enable the settings for
constants n01 to n79.
Execute VERIFY by
Constant Copy Function
Selection (n76).
Display the unmatched
constant No.
Display the constant
value in the Inverter.
Display the constant
value in the Digital
Operator.
Continue the execution
of VERIFY.
While a constant No. that is not the same is displayed or a constant
value is displayed, press STOP/RESET to interrupt the execution of the
verification. End will be displayed. Press DSPL or ENTER to return to
the constant No.
Explanation
Press DSPL to light
[PRGM].
Press ENTER to display the
set value.
Change the set value to 4
by pressing the
key.
Press ENTER.
Change the constant No. to
n76 by pressing the
key.
Press ENTER to display the
set value.
Change the set value to vFy
by pressing the
key.
Press ENTER.
Press ENTER.
Press ENTER.
Press the
key.
Press DSPL or ENTER.
6. Programming Features
(May be a different constant No.)
(Lit)
(May be a different constant No.)
or
(Flashes)
(Lit for one second.)
(The constant No. is displayed.)
or
(Lit)
(Lit)
or
(Flashes while executing VERI-
FY)
(Flashes) (When n011 is differ-
ent.)
(Flashes)
(Flashes)
(Flashes while executing the
verification)
(End is displayed when the verifi-
cation has been completed.)
(The constant No. is displayed.)
Operator Display