200 V Class Single-phase Input Inverters
Model
Terminal
Symbols
CIMR-
R/L1, S/L2, T/L3,
J7∗A
-, +1, +2
B0P1
U/T1, V/T2, W/T3
CIMR-
R/L1, S/L2, T/L3,
J7∗A
-, +1, +2
B0P2
U/T1, V/T2, W/T3
CIMR-
R/L1, S/L2, T/L3,
J7∗A
-, +1, +2
B0P4
U/T1, V/T2, W/T3
CIMR-
R/L1, S/L2, T/L3,
J7∗A
-, +1, +2, U/T1,
B0P7
V/T2, W/T3
CIMR-
R/L1, S/L2, T/L3,
J7∗A
-, +1, +2, U/T1,
B1P5
V/T2, W/T3
Note: 1. The wire size is given for copper wire at 75°C.
2. Do not use terminal T/L3 on Inverters with single-phase input.
Screws
Tightening
Torque
N m
M3.5
0.8 to 1.0
1.24
(10.97)
M3.5
0.8 to 1.0
1.24
(10.97)
M3.5
0.8 to 1.0
1.24
(10.97)
M3.5
0.8 to 1.0
M3.5
0.8 to 1.0
Applicable Size
Recommended
AWG
2
mm
mm
0.75 to 2
18 to 14
0.75 to 2
18 to 14
0.75 to 2
18 to 14
2 to 5.5
14 to 10
2 to 5.5
14 to 10
4. Wiring
Wires
Type
Size
AWG
2
2
14
600 V vinyl-
sheathed or
equivalent
2
14
2
14
3.5
12
2
14
5.5
10
2
14
27