3
Milling Cycles
3.17 High Speed Settings – CYCLE832 (SW 6.3 and higher)
3.17.5 Error messages
Explanation
Alarm source CYCLE832
Alarm number
61191
61192
61193
61194
3-270
Alarm text
"5-axis transformation not set up"
"Second 5-axis transformation not set
up"
"Compressor option not set up"
"Spline interpolation option not set up"
Explanation, remedy
1. Machining package five axes option
or multi-axis interpolation not set.
2. Check MD 24100:
$MC_TRAFO_TYPE_1 to
$MC_TRAFO_TYPE_8 for a valid
5-axis transformation type
Set spline interpolation option (A, B and C
splines/compressor function
SINUMERIK 840D/840Di/810D Programming Guide Cycles (PGZ) – 11.02 Edition