Instructions for fitting connectors, attachments and devices
2.5 Power supply
Procedure
Only use cables with the power plug PRO
that meet the following specifications:
Cable diameter
9 ... 13 mm
Cable cross section
2.5
mm
2
Cable cross section
10 x 2.2 10 x 1.7
AWG
Max. current at
16 A
ambient temperature
58 ℃
13 A
73 ℃
2. Strip 35 mm of the cable jacket.
Remove 10 mm of the insulation from the
wir
es.
70
1.5
a forcing nut
b sealing ring
16 A
c rear wall
45 ℃
d latch
13 A
e plug insert
60 ℃
f housing notch
g housing
3. With a wire cross section of 2.5
mm² (AWG14), crimp ferrules
DIN 46228-A2.5-10 (dimensions
see figure) to the wire ends. For
a wire cross section of 1.5 mm²
(16 AWG), use the DIN 46228-
A1.5-10 ferrules.
4. Push the wires into the spring
terminal clamps as shown in the
table.
1. Thread the forcing nut (a), the
sealing ring (b) and the back wall
(c) loosely over the cable.
PIN
1
2
3
4
5
5. Check that good contact is
established by pulling lightly on the
wires.
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01
PROFINET
L1
N1
L2
N2
FE