Siemens Cerberus CS1140 Planning page 54

Fire detection system
Hide thumbs Also See for Cerberus CS1140:
Table of Contents

Advertisement

CT11
C-Bus
oder
E3I020
K3I090
RS232
1
2
internal or
Printer
external printer
–> see page 82
Pager
–> see page 86
CT11
C-Bus
E3I020
RS232
1
2
Modules
Control terminals AlgoPilot B3Q6../565
B3Q...
Control terminal AlgoPilot
CT/CI/CA
Flash programm file
Z5B...
Inscription set
Control terminals AlgoPilot B3Q4../560
CT/CI/CA
EPROM set
Z3S070
504823
RAM set 512Kx8Bit
Z3S080
504836
RAM set 256Kx8Bit
Z5B...
Inscription set
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Additional display and operating equipment
B3Q321
565684
Fire department control terminal 'CH'
B3R051
490513
Parallel indicator terminal "2x24 indicators"
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Cabinets H23/H26/H28/H37/H38/H47/H67/H98../19"
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Accessories
V2G050
570611
Cable for 9V lithium battery
V2G040
475923
Cable for 9V lithium battery
E3I020
460239
RS232 module
Z1B020
475907
Mounting accessories for E3I020 / B3Q...
K3I090
510820
Pager interface
Z1B060
525983
Mounting accessories for K3I090 / B3Q...
Z3I530
484972
Adapter for K3R071/72, B3R051
F12A100
495275
Flat cable 'Micro' 12 cond., 0.4m
F12A470
495288
Flat cable 'Micro' 12 cond., 1.5m
E3I040
499310
LON interface
Z1B070
A5Q00001720 Mounting accessory for E3I040
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Autonomous power supply
B2F020
470588
Converter 115/230V
E3C011
505479
Battery charging unit
AX1210
475570
Battery 12V/15Ah
Z3I470
484341
Cable set for H38...
48
Fire & Security Products
Siemens Building Technologies Group
CC11
CI11
CK11
,
,
Mains
Batteries
B2F020
E3C011
AX12..
I-Bus
F12A100
B3R051
F12A100
B3R051:
– can be installed separately, however at max. 1000m
– max. 24 units, however max. 8 addresses
– free allocation of the LEDs (programming according to application)
– line and equipment not monitored
B3Q321
LON-Bus
24V
E3I040
I-Bus
not monitored
>29.6V
6A
AC
DC
B3Q321
LON-Bus
E3I040
24V supply line
Data bus
B3R051
CA11
E3I020
RS232
1
2
all variants of AlgoPilot Õ see page 42ff
for 'CT' / 'CI' / 'CA' ! see page 45
according to language Õ see page 45
for 'CT' /'CI' / 'CA' ! see page 46
for 'CT1142'
for 'CA1141'
according to language Õ see page 46
only CH
for details referring cabinets Õ see page 50 – 57
for 3rd power source for B3Q6../565
for 3rd power source for B3Q4../560
for connection printer or 'CA11'
for mounting E3I020 on the rear panel of AlgoPilot B3Q...
for connection of paging system/pager and internal/external printer
for mounting K3I090 on the rear panel of AlgoPilot B3Q...
to adapt flat cable to terminals
for B3R051
for B3R051
Converter between I-Bus and LON-Bus
essential when mounting E3I040 in housing H28G200
for connection AlgoPilot B3Q... with E3C011
separately connected
parallel indicator
activation of Mimic Display
Õ see page 70
Parallel branching permissible
max.
1000m
B3R051
F12A100/470
24V
I-Bus
for further details
Õ see page 13
Basic equipment
Option
B3R051
B3Q321
e4595e 15
05.2003

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents