Annex notes3-1: (APC) Please Configure as follows (CMU200).
1.Change to GSM850 Analyzer/Generator (Non-Signaling mode).
2.Change RF level Used TS –85dBm and RF level Unused TS –20dBm in Generator. And turn "ON" Generator.
3.Change channel to ch190 in Generator. (GSM900: ch62, GSM1800: ch699, GSM1900: ch662)
4.Change channel to ch190 in Analyzer. (GSM900: ch62, GSM1800: ch699, GSM1900: ch662)
5.Change Transmission mode to "Continuous".
6.Change Training Sequence to "OFF" in Analyzer.
7.Change cable lose of AF/RF.
Annex notes3-2: (APC) Please Configure as follows (HP8960)