RF Adaptor (Part No. PVRFJIG)
The RF Adaptor provides the connections bettween the test equipment and the phone for unit testing.
Figure 7.2. : RF Adaptor
A cable with SMA female connector is provided to make the RF connection. An SMA to N-Type male adaptor will be
required to connect the Jig to the service equipment. Cable losses for the RF connection are 0.5 dBM (GSM 900)
and 0.8 dBM (GSM 1800).
Data Cable (Part No. 73PV150001W)
The data cable for used to software download and calibration.
Figure 7.3. : Data Cable
RF Cable (Part No. JT00084)
The RF cable provides the necessary connections between the PCB Repair Jig/RF Adapter and external test equipment.
Case Separation Tool (Part No. JT00059)
The case Separation Tool is used to facilitate separation of the front cover and case.
Figure 7.4. : Case Separation Tool
GSM Tester
This unit acts as a base station providing all the necessary GSM signalling requirements and also provides GSM
signal measuring facilities.