Panasonic EB-G60 Service Manual page 75

Personal cellular telephone
Table of Contents

Advertisement

Annex notes 1
Test Set
1. Test mode (Bch+Tch)
2. Cell power –85 dBm
3. Cell band
HP8960
4. Broadcast channel
5. Cable lose
1. Analyzer/Generator
2. RF level used –85 dBm
Unsed –20 dBm
3. RF channel
CMU200
4. Transmission :
5. Cable lose
1. Module Test
2. RF GEN.
3. Freq/RF Chan
CMD55
4. RF level –85 dBm
5. Ramp Off
6. Cable lose
Annex notes2-1: (CMU200)
1.Change to GSM850 Analyzer/Generator (Non-Signaling mode).
2.Change RF level Used TS –85 dBm and RF level Unused TS –20 dBm in Generator. And turn on Generator.
3.Change channel to ch190 in Generator.(GSM900: ch62, GSM1800: ch699, GSM1900: ch662)
4.Change channel to ch190 in Analyzer.(GSM900: ch62, GSM1800: ch699, GSM1900: ch662)
5.Change Transmission mode to "Continuous".
6.Change cable lose of AF/RF.
Annex notes 2-2: (AGC, AFC) Please Configure as follows (HP8960)
AGC
1. Test mode (Bch+Tch)
2. Cell power –85 dBm
3. Cell band
4. Broadcast channel
5. Cable lose
1. Analyzer/Generator
2. RF level used –85 dBm
3. RF channel
4. Transmission :
Continuous
5. Cable lose
1. Module Test
2. Control channel.
3. RF level –85 dBm
4. Cable lose
– 8–17 –
AFC
1. Test mode (Bch+Tch)
2. Cell power –85 dBm
3. Cell band
4. Broadcast channel
5. Cable lose
6. MS Tx level
1. Analyzer/Generator
2. RF level used –85 dBm
Unsed –20 dBm
3. RF channel
4. Transmission : Burst
Continuous
5. Cable lose
6. Training Sequence : Off
1. Module Test
2. Trigger Mode : Power
3. Peak power : wide
4. RF level –85 dBm
5. Freq/RF Chan
6. Cable lose
APC
Unsed –20 dBm