p0043

BI: Enable energy usage display / Enab energy usage

Access level: 2
Can be changed: T, U
Unit group: -
Min:
-
Description:
Sets the signal source to enable/reset the process energy display in r0042.
BI: p0043 = 1 signal:
The process energy display is enabled in r0042.
Dependency:
See also: r0042
p0045

Display values smoothing time constant / Disp_val T_smooth

Access level: 3
Can be changed: T, U
Unit group: -
Min:
0.00 [ms]
Description:
Sets the smoothing time constant for the following display values:
r0063[1], r0068[1], r0080[1], r0082[1].
r0046.0...31

CO/BO: Missing enable signal / Missing enable sig

Access level: 1
Can be changed: -
Unit group: -
Min:
-
Description:
Display and BICO output for missing enable signals that are preventing the closed-loop drive control from being
commissioned.
Bit field:
Bit
00
01
02
03
04
08
10
11
12
16
17
18
19
20
21
25
26
27
30
31
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Signal name
OFF1 enable missing
OFF2 enable missing
OFF3 enable missing
Operation enable missing
DC braking enable missing
Safety enable missing
Ramp-function generator enable missing
Ramp-function generator start missing
Setpoint enable missing
OFF1 enable internal missing
OFF2 enable internal missing
OFF3 enable internal missing
Pulse enable internal missing
DC braking internal enable missing
Power unit enable missing
Function bypass active
Drive inactive or not operational
De-magnetizing not completed
Speed controller inhibited
Jog setpoint active
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
10000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parameters
7.3 Parameters
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
Factory setting:
0
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6799
Factory setting:
4.00 [ms]
Data type: Unsigned32
Dynamic index: -
Function diagram: 2634
Factory setting:
-
0 signal
FP
No
7954
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
361