Siemens SIMATIC NET SCALANCE W780 Series Configuration Manual page 449

Industrial wireless lan scalance w780/w740 to ieee 802.11n web based management
Hide thumbs Also See for SIMATIC NET SCALANCE W780 Series:
Table of Contents

Advertisement

Messages
File upload via TFTP: load of FileType <file type> OK
→ restart required
File upload via TFTP: load of FileType <file type> OK
File upload via TFTP: validation of FileType <file type>
IDENTICAL
File upload via TFTP: validation of FileType <file type>
FAILED
File upload via TFTP: file transfer of FileType <file type>
FAILED
File upload via TFTP: file transfer of FileType <file type>
failed. Cannot connect to given IP address
File download via TFTP: file transfer of FileType <file type>
failed. Cannot connect to given IP address
Messages error status
Messages
New Fault state:<fault description>
<fault description>:"Warm start performed." "Cold start
performed." "Link down on P1." "Link up on P1." "Power
down on line L1 (L2)" "DFS: No channels are available at
WLAN2"
Fault state gone: <fault description>
<fault description>:"Warm start performed." "Cold start
performed." "Link down on P1." "Link up on P1." "Power
down on line L1 (L2)" "DFS: No channels are available at
WLAN2" "C-PLUG not accepted. See System C-PLUG
mask for details."
New Fault state (reconfiguration): <fault description>
<fault description>:"Link down on P1." "Link up on P1."
"Power down on line L1 (L2)"
Fault state gone (reconfiguration): <fault description>
<fault description>:"Link down on P1." "Link up on P1."
"Power down on line L1 (L2)"
Fault state: <fault description> cleared.
<fault description>:"Warm start performed" "Cold start per-
formed".
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
Description
Loading the file using TFTP was successful. A restart is
required.
Loading the file using TFTP was successful.
Loading the file using TFTP was successful. The file is iden-
tical to the existing file.
Loading the file using TFTP failed. The file contains errors
or is invalid.
Loading the file using TFTP failed. The file name is incorrect
or the file does not exist on the server.
Loading the file using TFTP failed. The TFTP server cannot
be reached or the settings are incorrect.
Saving the file using TFTP failed. The TFTP server cannot
be reached or the settings are incorrect.
Description
You configure the events in "System > Events".
You configure the monitoring of the power supply and the
link on the Ethernet port in "System > Fault Monitoring".
Incoming fault.
Not all events automatically lead to a fault. On the "Events"
WBM page, you specify which events will be logged, for
example device restart, changed link on the Ethernet port.
Outgoing fault
Incoming fault.
The event was triggered due to a change in the configura-
tion.
Outgoing fault.
The event was triggered due to a change in the configura-
tion.
Fault was acknowledged by the user.
Appendix D
D.1 Messages in the event log
449