Configuring with Web Based Management
6.6 "Interfaces" menu
● Color Scheme
With this icon, you change the color scheme for the graphic type "Spectrogram":
– The color goes from the lowest value (-100 dBm) in black to the highest value (0 dBm)
– The color goes from the lowest value (-100 dBm) in red to the highest value (0 dBm) in
● Reset
With this icon you reset the maximum and average values of the graphic type "Realtime".
This table contains the following columns:
● Radio
Shows the WLAN interface to which the information applies.
● State
Shows the status of the measurement. The following values are possible:
– stopped
– running
● Frequency Band
Specify the frequency band.
● Center Frequency
Select the center frequency.
● Start
Click the button in this column to start the measurement.
● Stop
Click the button in this column to end the measurement.
Procedure
1. Select the required frequency band from the "Frequency Band" drop-down list.
2. Select the required center frequency from the "Center Frequency" drop-down list.
3. Click the "Start" button.
4. To stop the measurement, click the "Stop" button.
5. You can adapt the settings in the second table during the measurement.