Clearances; Location - Bosch HSV 745055 A Installation Instructions Manual

Table of Contents

Advertisement

Clearances

Clearances to combustible
materials

Location

Wall fixing
10
A range hood fitted above the top must be installed
according to the installation instructions for the range
hood. A minimum distance of 650 mm is required for
a range hood and 750 mm for an exhaust fan.
"Any adjoining wall surface (side or rear) situated
within 200 mm of any hob burner must be a suitable
non combustible material from the edge for a height
of 150 mm for the entire length of the cooker. Any
combustible construction above the cooker must be
at least 650 mm avobe the maintop."
Ensure that a power and gas supply are nearby. The
cooker should be located carefully so that the heat
produced by it has plenty of space to escape.
The cooker must be installed directly on the kitchen
floor and in accordance with the specified
dimensions.
Min
The distance between the top edge of the cooker and
650
the bottom edge of the extractor hood must comply
with the extractor hood manufacturer's instructions.
Caution - the appliance may no longer be shifted
once it is installed.
The distance from the high speed burner or WOK
burner to the front sections of adjacent furniture must
be at least 50 mm.
Appliance height (in mm) 900 mm
Appliance width (in mm)
Appliance depth (in mm) 600 mm
To prevent the cooker from tipping over, you must fix
the hook supplied to the wall and connect the chain
attached to the rear of the cooker to the hook.
600 mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents