    General Information Converting your appliance so that it can use a different type of gas must be carried out by an authorised expert or by the after sales service in accordance with these installation instructions. We assume no liability for damage and malfunctions caused by connection and setting errors.
  • Page 5: Important Information

    Important information For details regarding the connection of your appliance, see the rating plate on the rear of the appliance. Observe the symbols indicated on the rating plate. If a symbol for your country is not listed, follow the technical regulations valid for your country. Before setting up the appliance, enquire about the gas type and pressure of your local gas supply.
  • Page 6: Safety Considerations

    Safety considerations For your safety If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store articles on or against this appliance. Do not store flammable material near this appliance.
  • Page 7 2. Do not forget that the unit becomes hot when in use. Common sense is important. Just because the flame is out, does not mean parts connot still be hot. 3. This appliance shall not be used for space heating. This instruction is based on safety considerations.
  • Page 8 16.Never pour water on burning fat or oil. DANGER OF BURNS! Cover the receptacle to smother the flames and turn the hob off. 17.In the event of a fault, cut the gas and electricity supplies to the appliance. Call our Service Centre to repair the fault.
  • Page 9: Installation

    Installation Preparing to install This installation must conform with the following: Manufacturer's Installation instructions Local Gas Fitting Regulations Municipal Building Codes AGA Installation Code for Gas Burning Appliances (AS 5601/AG 601). S.A.A. Wiring Code Local Electrical Regulations Any other statutory regulations Only an officially authorised technician should connect the appliance.
  • Page 10: Clearances

    Clearances A range hood fitted above the top must be installed according to the installation instructions for the range hood. A minimum distance of 650 mm is required for a range hood and 750 mm for an exhaust fan. Clearances to combustible "Any adjoining wall surface (side or rear) situated materials within 200 mm of any hob burner must be a suitable...
  • Page 11: Connection

    Connection Electrical An electrical 16 amp socket needs to be within 1,20 m of the cooker to allow electrical connection. The socket must remain accessible after installation of the appliance. Important note: This appliance is connected to the mains (230 VAC) by means of the connecting lead which must be fixed to the kitchen unit to prevent it from coming into contact with hot parts of the cooker.
  • Page 12: Warning To The Installer

    WARNING TO THE INSTALLER INSTALLATION WITH A Only install with a hose assembly that complies with HOSE ASSEMBLY AS/NZS 1869 (AGA Approved), 10mm ID, class B or D, no more than 1.2 m long and in accordance with AS5601. Ensure that the hose does not contact the hot surfaces of the hotplate or an oven, dishwasher or other appliance that may be installed next to the cooker.
  • Page 13: Selecting The Side For The Gas Connection

    Note: The hose restraint chain supplied should be used if the appliance is connected with a hose assembly. One end of the chain should be attached to the screw located at the rear of the maintop (above the gas inlet connection) and the other end should be connected to the wall fixing hook.
  • Page 14: Location

    Location The cooker must be installed directly on the kitchen floor and in accordance with the specified dimensions. The distance between the top edge of the cooker and the bottom edge of the extractor hood must comply with the extractor hood manufacturer's instructions. Caution - the appliance may no longer be shifted once it is installed.
  • Page 15: Type Of Connection

    Type of connection Country ISO 7 1 Australia New Zealand Converting the type of gas replace the gas connecting piece To convert the type of gas replace the burner nozzles replace the bypass nozzles on the burner taps or close them to the limit stop The diameters with the corresponding values are specified on the nozzles.
  • Page 16: Parts For Gas Conversion

    Note: After the conversion, make sure that you take the sticker indicating the type of gas specification from the cover and attach it to the rating plate over the existing table. Enter the new type of gas and new gas pressure in the table.
  • Page 17: Connection For Natural Gas (Ng)

    Connecting thread Blind plug (locking piece) Gas Pressure Regulator Connection for natural gas (NG) With natural gas (NG), the gas connection is made via a gas tube or a flexible security tube equipped with a screw thread at both ends. Connection in accordance with ISO 7 1 1.
  • Page 18: Replacing The Burner Nozzles

    4. The gas pressure regulator supplied with the appliance must be installed in line with the gas pipe (NG only). Carry out a leak test, see the "Leak test" section. Open the locking device for the gas connection. Note Observe the country specific requirements. Replacing the burner nozzles Turn all control knobs on the control panel to Off.
  • Page 19 Disconnect the appliance from the mains. Danger of electric shock. Turn all control knobs in the control panel to off. Grip each control knob at its contact points on the control panel. Pull it forwards slightly and carefully remove it. If the appliance was set to natural gas at the time of Initial conversion of the appliance from universal...
  • Page 20 Open the oven door and place a tea towel on the door. Remove both screws (M4) in openings 1 and 4 from their position on the right hand side of the control panel. Then remove the two function selector screws. Grip the panel with both hands and slowly pull it upwards.
  • Page 21 Remove the four ignition switches. For models with a burner safety device Use a screwdriver (no. 2) for slotted screws to tighten the nozzles above as far as possible. Refit the control panel: Grip the panel with both hands and slowly fit it into place.
  • Page 22: Leak Test And Function Test

    Leak test and function test Make sure that no sparks are generated. Do not use fire or naked flames. There is a risk of explosion. Check the tightness with suitable foam. If gas escapes Close the locking device. Ventilate the room sufficiently. Check the gas and nozzle connections once more.
  • Page 23: Checking The Bypass Nozzles

    Moisten the area around the nozzle with foam. Push in the control knob and turn it anti clockwise. Gas is supplied in this way. If the foam dissolves or gas escapes, see "If gas escapes". Checking the bypass nozzles Open the locking device for the gas connection. Check each bypass nozzle individually for leaks.
  • Page 24: Technical Data - Gas

    Turn the control knobs to a small flame setting. The flame safety system must remain in the "small flame" setting for about 1 minute. Check the evenness of the burning for both larger and smaller flames. The flame must burn evenly and continuously.