Jts315La - Jet JTS-315LA Operating Instructions Manual

Circular saw bench
Hide thumbs Also See for JTS-315LA:
Table of Contents

Advertisement

Test Report No.: No.: 17706687 001
Part II of II
Requirement  Test
Clause
11.4
Operating time
11.5
Thermal cut-outs not operate and temperature rise
not exceed table 2
11.6
Temperature rise of windings exceeding limits of
11.5
12
LEAKAGE CURRENT
12.1
Leakage current under normal use condition
Measurement of leakage current .............................: The tool is switched on:
12.2
Conditions for measurement
Location of poles
Limits
Single pole switch
Tools with heating elements
13
ENVIRONMENT CONDITIONS
13.1
Dust measuring
Dust collecting device capability specified by the
manufacturer
Measurement of dust collecting capability ...............:
13.2
Noise
Page 16 of 63
EN 61029-1:2009+A11
Result - Remark
TS-315D: 1.06Ur: 90min,
0.94Ur: 90min
TS-315G: 1.06Ur: 77min,
0.94Ur: 119min
Not applicable
Limit of 11.5 not exceeded.
The leakage current is
measured immediately after
the temperature rise test with
1.06Ur.
TS-315D:
L/N- Tool enclosure:
0.046/0.088mA
L/N- Switch box:
0.001/0.001mA
L/N- Motor enclosure:
0.049/0.090mA
TS-315G:
N- Tool enclosure:
0.039/0.085mA
N- Switch box: 0.001/0.001mA
N- Motor enclosure:
0.041/0.087mA
Class I tool: 0.75mA
Class II tool: 0.25mA
Verdict
P
N/A
N/A
P
P
P
P
P
P
N/A
N/A
P
N/A
N/A
N/A
P

Advertisement

Table of Contents
loading

Table of Contents