SEZ S
C
ERIES
OUNTERTOP
ELECTRICAL REQUIREMENTS
One electrical connection is required to the fuse block of the steamer. All units shipped per customer order,
three phase or single phase (a kit is available for field conversion to three phase or single phase). Circuit
must be wired for the maximum amps at required voltage.
Voltage
208 V
220 V
240 V
480 V
WATER REQUIREMENTS
To meet warranty requirements, the water supply must be as follows:
Connection
Pressure
Total Dissolved Solids (TDS)
Hardness
pH
Typical usage is 0.02 gpm. Maximum instantaneous usage is 0.12 gpm.
In order to minimize service problems and to meet the warranty requirements, a water treatment system
(softener) is recommended when water quality does not meet the limits stated above.
DRAIN REQUIREMENTS
The drain outlet has a 3/8" NPT (male) connector. DO NOT directly connect the drain to a plumbing system
unless you also install an "open funnel" downstream of this connection. There must be no back-flow or back-
pressure into the drain connection!
CONSTRUCTION SPECIFICATIONS
Exterior: Type 304 stainless steel with #3 sanitary finish.
Interior: #304 stainless steel.
Power Source: One electric power source for controls and heating elements, as well as one ground wire.
A positive ground connection is essential.
Cooking Compartment: Fully insulated.
CONTROLS
ON/OFF Lever: In the "OFF" position, the power is off and the drain valve is open. In the "ON" position, the
power is on and the drain valve is closed.
60 Minute Timer: Time can be set between 1 and 60 minutes. When time expires, buzzer sounds. Buzzer
can be disabled by turning the knob to manual position. Timer has no effect on the operation of the
steamer.
"SERVICE REQUEST" Light: Unit signals when service is needed.
"ON" Light: Indicates power is on.
O
S
TEAMERS
Model SEZ/3
1 Phase
44
41
38
19
1/4" NPT (female)
cold water
30 to 60 PSI
60 PPM
2 grains or 35 PPM
7.0 to 7.5
'
M
1183437
PERATOR
S
ANUAL
Total Connected Amps
Model SEZ/5
3 Phase
1 Phase
25
57
24
54
22
49
11
25
S
PECIFICATIONS
3 Phase
33
31
29
15
P
5
AGE